Related Experiment Video
Updated: May 10, 2025

Estimation of Contact Regions Between Hands and Objects During Human Multi-Digit Grasping
Published on: April 21, 2023
A novel technique for digital assessment of hand volume
Nastaran Katouzian1, Claire A Parent2, Roy Eagleson1
1Faculty of Engineering, Western University, London, Ontario, Canada.
Background:
Swelling is an anticipated nonspecific response following hand trauma, arthritis, infection, or surgery, which can decrease range of motion and increase pain. Approaches to quantify swelling, typically performed through hand volume measurement, are lacking in routine clinical assessments. A hand volumetry technique that is quick, inexpensive, noninvasive, and reliable is still in demand. With advances in computer imaging, new technologies are increasingly gaining attention to enable the digital assessment of hand volume as a surrogate marker of swelling.
Purpose:
This study aims to develop a webcam-based method using computer vision technology for digital hand volume assessment and compare its results with those from conventional water displacement and figure-of-eight techniques to evaluate its feasibility in healthy hands.
Study Design:
Cross-sectional observational pilot study.
Methods:
A novel algorithm was developed to process hand images captured through a webcam. Digital hand volume was computed using both palmar and lateral view area calculations. Thirty healthy participants were recruited. The volumes of their hands were measured using three methods: the proposed digital method (VD), water displacement (VW), and figure-of-eight taping (CFOE). Digital volumes were compared to conventional approaches using Pearson correlation coefficients and Bland-Altman analysis.
Results:
A strong correlation was observed between VD and CFOE (r=0.89, p<0.00001). Similarly, VD demonstrated a significant correlation with VW (r=0.96, p<0.00001). However, a systematic overestimation by VD was identified and subsequently adjusted using a calibration curve derived from regression analysis, resulting in the calibrated hand volume (VD*). Bland-Altman analysis between VD* and VW indicated Limits of Agreement (LOA) of ±33.6 mL, with percentage limits ranging from -9.5% to 9.3%.
Conclusions:
This study demonstrates a novel approach to digital hand volume assessment. Our findings suggest that when LOA of ±9.5% is considered clinically acceptable, the digital method can be used interchangeably with water displacement volumetry in nonpathological hands.
Related Concept Videos
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:

