Improving the Protection of Step-Down Transformers by Utilizing Percentage Differential Protection and
Chia-Wei Huang1, Chih-Chiang Fang2, Wei-Tai Hsu1
1Department of Electrical Engineering, Zhaoqing University, Zhaoqing 526061, China.
Abstract:
Transformer operations are susceptible to both internal and external faults. This study primarily employed software to construct a power system simulation model featuring a step-down transformer. The simulation model comprised three single-phase transformers with ten tap positions at the secondary coil to analyze internal faults. Additionally, ten fault positions between the power transformer and the load were considered for external fault analysis. The protection scheme incorporated percentage differential protection for both the power transformer and the transmission line, aiming to explore fault characteristics. To mitigate the protection device's sensitivity issues, the scale-dependent intrinsic entropy method was utilized as a decision support system to minimize power system protection misoperations. The results indicated the effectiveness and practicality of the auxiliary method through comprehensive failure analysis.
More Related Videos
06:17Quantifying the Relative Thickness of Conductive Ferromagnetic Materials Using Detector Coil-Based Pulsed Eddy Current Sensors
Published on: January 16, 2020
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Differential Relays
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...