Related Experiment Video
Updated: Jun 26, 2026

An Improved Mechanical Testing Method to Assess Bone-implant Anchorage
Published on: February 10, 2014
Comparison of Different Materials in the Same-Sized Cemented Stems on Periprosthetic Fractures in Bone Models
Kohei Hashimoto1, Yukio Nakamura1,2, Nobunori Takahashi1
1Department of Orthopedic Surgery, Aichi Medical University, 1-1 Yazakokarimata, Nagakute 480-1195, Aichi, Japan.
Abstract:
Objective: The increasing number of aging patients with total hip arthroplasties (THA) causes an increased incidence of periprosthetic fractures (PPF). The study aimed to evaluate the impacts of two different materials in the same-sized cemented stems on PPF in bone models. Methods: This study compared the maximum rotational torque leading to PPF when stems made of cobalt-chromium-molybdenum (Co-Cr-Mo) alloy and stainless use steel (SUS) were implanted using simulated bone models (Sawbones, 3403). The maximum destruction torque was compared statistically for each material (Co-Cr-Mo alloy vs. SUS stainless steel) in this model, and fracture patterns were examined. Results: The PPF occurred with a spiral propagation from the proximal femur towards the diaphysis, with breakage occurring near the distal end of the stem. There were no significant differences in the destruction torque values between the Co-Cr-Mo alloy (103.0 ± 14.9 Nm) and SUS (98.7 ± 15.1 Nm) samples (p = 0.575). The fractures using the bone models exhibited similar patterns in all specimens, resembling clinical PPF fracture types clinically, specifically Vancouver classification B2. Conclusions: The comparison of the maximum destruction torques of the Co-Cr-Mo alloy and SUS cemented stems in simulating PPF showed no significant differences. The results suggest that the materials of the cemented stems might not significantly affect the occurrence of PPF in THA.
More Related Videos
08:04Proximal Cadaveric Femur Preparation for Fracture Strength Testing and Quantitative CT-based Finite Element Analysis
Published on: March 11, 2017
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Related Concept Videos
Bone Remodeling
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Bones of the Upper Limb: Humerus
Bones of the Lower Limb: Femur and Patella
Bones of the Lower Limb: Tibia and Fibula
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...