Clinical Assessment of Automated Non-Contact Tonometer: Interchangeability with Goldmann Applanation Tonometry and
Michael Chaglasian1, Huiyuan Hou2, Mayra Tafreshi2
1Illinois College of Optometry, Chicago, IL 60616, USA.
Abstract:
Background/Objectives: This study aimed to evaluate the clinical interchangeability of intraocular pressure (IOP) measurements between a non-contact tonometer (NCT), the TRK-3 OMNIA, and Goldmann applanation tonometry (GAT) and to assess the repeatability of TRK-3 measurements. Methods: This prospective, multicenter study included 120 subjects stratified into three IOP groups based on GAT measurements: low IOP (7-16 mmHg), intermediate IOP (>16 to <23 mmHg), and high IOP (≥23 mmHg). The study eye was randomly selected from each subject. IOP was measured using both TRK-3 OMNIA and GAT following a standardized protocol. Agreement between the two methods was evaluated using Bland-Altman analysis, 95% limits of agreement (LoA), and equivalence testing via the two one-sided test (TOST) approach with a predefined ±5 mmHg margin. Linear regression analysis was performed to characterize the relationship between TRK-3 and GAT measurements. The repeatability of TRK-3 measurements was assessed using the intraclass correlation coefficient (ICC), repeatability limit, and coefficient of variation (CV). Results: Across all subjects, the mean difference between TRK-3 OMNIA and GAT IOP measurements was -0.2 mmHg. TRK-3 OMNIA overestimated IOP in the low IOP group (mean difference: 2.1 mmHg, LoA: -1.2 to 5.4 mmHg) and underestimated in the high IOP group (mean difference: -2.4 mmHg, LoA: -5.9 to 1.1 mmHg), while agreement was highest in the intermediate IOP group (-0.2 mmHg, LoA: -2.9 to 2.5 mmHg). Despite the systematic trend, equivalence testing confirmed statistical equivalence across all groups, with 90% confidence intervals (CI) of 1.7 to 2.5 mmHg (low IOP group), -0.6 to 0.2 mmHg (intermediate IOP group), and -2.9 to -2.0 mmHg (high IOP group). Linear regression analysis found a strong correlation (r = 0.92) between TRK-3 and GAT. The TRK-3 OMNIA demonstrated good repeatability, with an ICC of 0.94, a repeatability limit of 3.12 mmHg, and a CV of 5.65%. The repeatability limits were 2.22 mmHg, 2.60 mmHg, and 4.19 mmHg in the low, intermediate, and high IOP groups, respectively. Conclusions: TRK-3 OMNIA and GAT measurements showed strong agreement, statistical equivalence, and a high correlation, supporting their clinical interchangeability. TRK-3 also demonstrated high repeatability. These findings indicate that this automated non-contact tonometer provides reliable and repeatable IOP measurements, supporting its integration into routine clinical workflows.
Related Concept Videos
Assessment of blood pressure in brachial artery(two-step method)
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...