Related Experiment Video
Updated: May 9, 2025

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Intermittent hypoxemia during hemodialysis: AI-based identification of arterial oxygen saturation saw-tooth pattern
Hanjie Zhang1, Andrea Nandorine Ban2, Peter Kotanko2,3
1Renal Research Institute, 315 East 62nd Street, 3rd Floor, New York, NY, 10065, USA. Hanjie.Zhang@RRINY.COM.
Background:
Maintenance hemodialysis patients experience high morbidity and mortality, primarily from cardiovascular and infectious diseases. It was discovered recently that low arterial oxygen saturation (SaO2) is associated with a pro-inflammatory phenotype and poor patient outcomes. Sleep apnea is highly prevalent in maintenance hemodialysis patients and may contribute to intradialytic hypoxemia. In sleep apnea, normal respiration patterns are disrupted by episodes of apnea because of either disturbed respiratory control (i.e., central sleep apnea) or upper airway obstruction (i.e., obstructive sleep apnea). Intermittent SaO2 saw-tooth patterns are a hallmark of sleep apnea. Continuous intradialytic measurements of SaO2 provide an opportunity to follow the temporal evolution of SaO2 during hemodialysis. Using artificial intelligence, we aimed to automatically identify patients with repetitive episodes of intermittent SaO2 saw-tooth patterns.
Methods:
The analysis utilized intradialytic SaO2 measurements by the Crit-Line device (Fresenius Medical Care, Waltham, MA). In patients with an arterio-venous fistula as vascular access, this FDA approved device records 150 SaO2 measurements per second in the extracorporeal blood circuit of the hemodialysis system. The average SaO2 of a 10-second segment is computed and streamed to the cloud. Periods comprising thirty 10-second segments (i.e., 300 s or five minutes) were independently adjudicated by two researchers for the presence or absence of SaO2 saw-tooth pattern. We built one-dimensional convolutional neural networks (1D-CNN), a state-of-the-art deep learning method, for SaO2 pattern classification and randomly assigned SaO2 time series segments to either a training (80%) or a test (20%) set.
Results:
We analyzed 4,075 consecutive 5-minute segments from 89 hemodialysis treatments in 22 hemodialysis patients. While 891 (21.9%) segments showed saw-tooth pattern, 3,184 (78.1%) did not. In the test data set, the rate of correct SaO2 pattern classification was 96% with an area under the receiver operating curve of 0.995 (95% CI: 0.993 to 0.998).
Conclusion:
Our 1D-CNN algorithm accurately classifies SaO2 saw-tooth pattern. The SaO2 pattern classification can be performed in real time during an ongoing hemodialysis treatment, provide timely alert in the event of respiratory instability or sleep apnea, and trigger further diagnostic and therapeutic interventions.
More Related Videos
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: