Multi-Modal Home Sleep Monitoring in Older Adults
Published on: January 26, 2019
A Dual-Modal Wearable Pulse Detection System Integrated with Deep Learning for High-Accuracy and Low-Power Sleep
Jia Wang1, Jiangtao Xue2,3, Yang Zou2,3
1Department of Cardiology, Beijing Hospital, National Center of Gerontology, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences & Peking Union Medical College, Beijing, 100730, China.
Abstract:
Despite being a serious health condition that significantly increases cardiovascular and metabolic disease risks, sleep apnea syndrome (SAS) remains largely underdiagnosed. While polysomnography (PSG) remains the gold standard for diagnosis, its clinical application is limited by high costs, complex setup requirements, and sleep quality interference. Although wearable devices using photoplethysmography (PPG) have shown promise in SAS detection, their continuous operation demands substantial power consumption, hindering long-term monitoring capabilities. Here, a dual-modal wearable system is presented integrating a piezoelectric nanogenerator (PENG) and PPG sensor with a biomimetic fingertip structure for SAS detection. A two-stage detection strategy is adopted where the self-powered PENG performs continuous preliminary screening, activating the PPG sensor only when suspicious events are detected. Combined with a Vision Transformer-based deep learning model, the high-accuracy configuration achieves 99.59% accuracy, while the low-power two-stage approach maintained 94.95% accuracy. This dual-modal wearable pulse detection system provides a practical solution for long-term SAS monitoring, overcoming the limitations of traditional PSG while maintaining high detection accuracy. The system's versatility in both home and clinical settings offers the potential for improving early detection rates and treatment outcomes for SAS patients.
More Related Videos
06:37Author Spotlight: Addressing Technical and Subjective Challenges in Measuring Classroom Attention
Published on: December 15, 2023
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Neural Control of Respiration
Respiratory Centers in the Brainstem
Two primary areas comprise the respiratory center: the medullary respiratory center in the medulla oblongata and the pontine respiratory group in the pons. The...
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: