Related Experiment Video
Updated: May 9, 2025

Author Spotlight: Developing a Simple and Robust Hepatic Model for Pharmacological and Toxicological Applications
Published on: October 20, 2023
Variations in Serum Albumin Levels Over Time in Patients Treated With Conventional Hemodialysis or Expanded
Juan C Castillo1, Jasmin Vesga2, Angela Rivera3
1Renal Care Services Soacha, Bogota, Colombia.
Introduction:
Hypoalbuminemia is a well-established risk factor for mortality in chronic hemodialysis (HD) patients. To evaluate the association of time-varying serum albumin with the type of dialyzer, we analyzed serum albumin over time in two cohorts of HD patients, one receiving HDx therapy enabled by the Theranova dialyzer and the other conventional HD with high-flux dialyzer (HF-HD).
Methods:
In this cohort study, 1092 prevalent adult HD patients (mean age 61 years; 62% men; 42% had diabetes; 19% had cardiovascular disease) at Renal Care Services Colombia undergoing either HDx therapy enabled by Theranova dialyzer (n = 559) or HF-HD (n = 533) were enrolled between September 1, 2017, and November 30, 2017, and then underwent repeated measurements of serum albumin for up to 48 months. Sociodemographic and clinical, and laboratory characteristics at baseline were recorded, and a repeated-measures analysis of variance (ANOVA) was conducted to examine differences in means of serum albumin at different time points. To evaluate the association between dialysis membrane and albumin levels during the follow-up, a linear panel regression analysis was performed, allowing control for imbalances in the cohorts of baseline clinical and demographic variables, as well as the time-dependent variables.
Results:
Mean albumin concentration remained above 3.8 g/dL and did not differ over time between HDx and HF-HD (p = 0.789). No association (p = 0.208) between serum albumin levels varying over time and the use of the Theranova dialyzer was found in the linear panel regression model. However, serum albumin was linked to both inflammatory and nutritional markers, including C-reactive protein, ratio of platelets to lymphocytes, and protein-energy wasting.
Conclusion:
Variations in serum albumin levels over time were associated with protein-energy wasting, inflammation, high age, vascular access, and hospitalizations, but not with the type of dialyzer.
More Related Videos
Related Concept Videos
Factors Affecting Protein-Drug Binding: Patient-Related Factors
Age stands as a key determinant in protein-drug binding. Neonates, characterized by low albumin content, experience heightened concentrations of unbound drugs such as phenytoin and...
Drug Distribution: Plasma Protein Binding
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...
Factors Affecting Protein-Drug Binding: Protein-Related Factors
The physicochemical properties of a drug play a significant role in its ability to bind to proteins. Lipophilic drugs, which dissolve in fats, oils, and lipids, can be...
Factors Affecting Renal Clearance: Renal Impairment
One condition associated with renal failure is uremia. Uremia is characterized by impaired glomerular filtration and fluid accumulation in the body. This condition hinders the renal clearance of drugs, resulting in drug accumulation and potential...
Nonlinear Pharmacokinetics: Bioavailability and Protein-Drug Binding
To quantify the extent of bioavailability, pharmacologists often use a parameter called .

