Influence of kindergarten dormitory bed layout on the proximity propagation characteristics of exhaled pollutants
Related Experiment Video
Updated: May 9, 2025

Lab-Scale Model to Evaluate Odor and Gas Concentrations Emitted by Deep Bedded Pack Manure
Published on: July 19, 2018
Yanhui Mao1, Yongsheng Wang2, Lina Zhang1
1Department of Architectural Environment, Ningbo University of Technology, Ningbo, China.
Insights
Kindergarten bed layouts significantly impact respiratory disease spread. Staggered bed heights improve ventilation, reducing airborne particle concentration in children's napping areas.
Area of Science:
- Environmental Health
- Indoor Air Quality
- Public Health
Background:
- Kindergarten dormitories are high-risk environments for respiratory disease transmission due to close proximity and extended occupancy.
- Understanding pollutant and aerosol spread between adjacent beds is crucial for mitigating disease transmission.
Purpose of the Study:
- To investigate the transmission characteristics of carbon dioxide (CO2) and simulated cough aerosols between adjacent beds in two common kindergarten dormitory layouts.
- To evaluate the impact of ventilation modes and sleeping postures on pollutant and aerosol concentrations.
Main Methods:
- Experiments were conducted using two bed layouts: three beds of staggered height (TBSH) and three beds of uniform height (TBUH).
- CO2 and PM2.5 concentrations were measured in the breathing zones of mannequins under various ventilation (on/off) and sleeping conditions.
- Liquid aerosols generated by an ultrasonic nebulizer served as surrogates for cough particles.
Main Results:
- Without ventilation, CO2 levels reached nearly 1,000 ppm within 60 minutes. With ventilation, CO2 diluted to ambient levels in 3.3 minutes.
- Unlike CO2, aerosols accumulated downstream, forming high-concentration zones at adjacent beds, even with ventilation.
- Increasing bed heights along the ventilation airflow direction effectively reduced downstream aerosol concentrations.
Conclusions:
- CO2 is an unreliable tracer for aerosol transmission in kindergarten dormitories.
- Bed layout and ventilation system integration are critical for reducing pollutant residence time in children's breathing zones.
- Kindergarten design should prioritize local dilution efficiency and airflow velocities exceeding 0.01 m/s near beds.
Abstract:
Kindergarten dormitories are indoor napping areas where preschool children spend extended periods nearby, making them high-risk environments for the transmission of respiratory diseases. To understand the transmission characteristics of respiratory pollutants, particularly CO2 and simulated cough aerosols between adjacent beds, two common bed layouts in kindergartens were investigated: three beds of staggered height (TBSH) and three beds of uniform height (TBUH). The experiments measured CO2 and PM2.5 concentrations (using liquid aerosols generated by an ultrasonic nebulizer as surrogates for cough particles) in the breathing zone of mannequins under different ventilation modes (on and off) and sleeping postures (lying face up and on the right side). The results showed that when ventilation was off, CO2 concentration near the head of each bed reached nearly 1,000 ppm within 60 min. When ventilation was on, CO2 concentration was diluted to ambient levels within 3.3 min. However, when the ventilation was on, aerosols exhibited different propagation characteristics compared to CO2. While CO2 was rapidly diluted, aerosols accumulated downstream and formed high-concentration zones at adjacent downstream beds. These findings visualize the potential aerosol transmission pathways between beds in kindergarten dormitories and highlight the limitations of using CO2 as an aerosol transmission tracer. The study found that increasing bed heights along the ventilation airflow direction effectively reduced downstream aerosol concentrations and compensated for the insufficient horizontal distance in kindergarten dormitories. Kindergarten design standards should consider local dilution efficiency in the breathing zone, and bed layouts should be integrated with the ventilation system to ensure air velocities exceed 0.01 m/s near the head, thereby reducing the residence time of pollutants in the breathing zone.
Related Concept Videos
Lung Capacity
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
External and Internal Respiration
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...