Feasibility of virtual T2-weighted fat-saturated breast MRI images by convolutional neural networks
Andrzej Liebert1, Dominique Hadler2, Chris Ehring2
1Institute of Radiology, Universitätsklinikum Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany. andrzej.liebert@uk-erlangen.de.
Background:
Breast magnetic resonance imaging (MRI) protocols often include T2-weighted fat-saturated (T2w-FS) sequences, which support tissue characterization but significantly increase scan time. This study aims to evaluate whether a 2D-U-Net neural network can generate virtual T2w-FS (VirtuT2w) images from routine multiparametric breast MRI images.
Methods:
This IRB-approved, retrospective study included 914 breast MRI examinations from January 2017 to June 2020. The dataset was divided into training (n = 665), validation (n = 74), and test sets (n = 175). The U-Net was trained using different input protocols consisting of T1-weighted, diffusion-weighted, and dynamic contrast-enhanced sequences to generate VirtuT2. Quantitative metrics were used to evaluate the different input protocols. A qualitative assessment by two radiologists was used to evaluate the VirtuT2w images of the best input protocol.
Results:
VirtuT2w images demonstrated the best quantitative metrics compared to original T2w-FS images for an input protocol using all of the available data. A high level of high-frequency error norm (0.87) indicated a strong blurring presence in the VirtuT2 images, which was also confirmed by qualitative reading. Radiologists correctly identified VirtuT2 images with at least 96% accuracy. Significant difference in diagnostic image quality was noted for both readers (p ≤ 0.015). Moderate inter-reader agreement was observed for edema detection on both T2w-FS images (κ = 0.49) and VirtuT2 images (κ = 0.44).
Conclusion:
The 2D-U-Net generated virtual T2w-FS images similar to real T2w-FS images, though blurring remains a limitation. Investigation of other architectures and using larger datasets is necessary to improve potential future clinical applicability.
Relevance Statement:
Generating VirtuT2 images could potentially decrease the examination time of multiparametric breast MRI, but its quality needs to improve before introduction into a clinical setting.
Key Points:
Breast MRI T2w-fat-saturated (FS) images can be virtually generated using convolutional neural networks. Image blurring in virtual T2w-FS images currently limits their clinical applicability. Best quantitative performance could be achieved when using full dynamic-contrast-enhanced acquisition and DWI as input of the neural network.