Evaluating photon-counting computed tomography for quantitative material characteristics and material differentiation
Didier Lustermans1, Gabriel Paiva Fonseca1, Cécile Jeukens2
1Department of Radiation Oncology (Maastro), GROW Research Institute for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, The Netherlands.
Abstract:
Objective.Photon-counting computed tomography (PCCT) counts the individual photons and measures their energy, which allows for energy binning and thereby multi-energy CT imaging. It is expected that quantitative data can be accurately extracted from the images and enable accurate material separation, yet its potential in radiotherapy is mostly unexplored. In this study, PCCT was assessed by evaluating estimation accuracies for relative electron density (RED), effective atomic number (Zeff), and proton stopping-power ratio (SPR), as well as the potential for material differentiation.Approach.PCCT images of a Gammex Advanced Electron Density phantom (Sun Nuclear) with tissue-equivalent materials were acquired in a small and large phantom setup on a NAEOTOM Alpha PCCT scanner (Siemens Healthineers). The scans were performed at 120 and 140 kVp, and virtual monoenergetic images (VMIs) were generated. These VMIs were used to estimate RED,Zeff, and SPR based on two calibration methods for each of the two phantom sizes. These results were compared to findings obtained based on dual-energy CT (DECT) scans acquired on a SOMATOM Confidence scanner (Siemens Healthineers) at 80 and 140 kVp, by using the low and high energy pair and VMIs. Calibration accuracy was quantified by the root-mean-squared error. Additional, material differentiation was assessed for both tissue-equivalent and calcium/iodine inserts by creating [RED/Zeff]-space plots.Main results.There was minimal differences between the two PCCT x-ray spectra, with SPR errors below 0.8% for the large phantom and 0.7% for the small phantom, which was comparable to DECT using VMIs. Material differentiation showed similar results for DECT and PCCT using VMIs, and resulted in lessZeffspread, than the regular DECT kVp pair, possibly due to denoising.Significance.This study showed the ability of PCCT to retrieve material characteristics and possibility for material differentiation between tissue-equivalent material and calcium/iodine, with results comparable to DECT.
More Related Videos
06:33Construction of a Preclinical Multimodality Phantom Using Tissue-mimicking Materials for Quality Assurance in Tumor Size Measurement
Published on: July 29, 2013
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET