Related Experiment Video
Updated: May 9, 2025

Assessment of Respiratory Function in Conscious Mice by Double-chamber Plethysmography
Published on: July 10, 2018
Exploring the Long-Term Utility of Remotely Monitored FeNO Suppression Testing in Severe Asthma
John Busby1, Joshua Holmes1, Mohammed Almutairi2
1School of Medicine, Dentistry and Biomedical Sciences, Queen's University Belfast, Belfast, UK.
Background:
Confirmation of optimal inhaled corticosteroid use is essential before initiating biologic therapy. Fractional exhaled nitric oxide (FeNO) suppression testing (FeNOSuppT) is a proven phenotyping technique; however, its long-term effect on clinical outcomes remains unclear.
Objectives:
To assess the real-world feasibility of delivering FeNOSuppT alongside digital inhaler monitoring and to examine its effect on biologic initiation and clinical outcomes.
Methods:
Prospective cohort study within 7 U.K. severe asthma centers. Patients received a sensor-enabled inhaled corticosteroid/long-acting β-agonist (ICS/LABA) inhaler during an initial appointment between July 2020 and June 2022. A positive FeNOSuppT was defined as greater than 42% FeNO reduction at short-term follow-up (typically 1-3 mo postbaseline). Biologic initiation and clinical outcomes were compared at short-term and long-term (typically 12 mo postbaseline) follow-up.
Results:
Of 353 included patients, 257 (72.8%) completed the FeNOSuppT and 140 (54.5%) were positive. A positive FeNOSuppT was associated with greater improvements in the % predicted short-term forced expiratory volume in 1 second (FEV1%; 8.6% vs -0.3; P < .001) and the 6-Item Asthma Control Questionnaire (ACQ6; 0.7 vs 0.3; P = .001) compared with a negative test. Of 168 patients eligible for biologics who completed the FeNOSuppT, those with a positive result initiated biologics less often (48.2% vs 65.2%; P = .035). Despite this, there was a greater improvement in FEV1 (11.0% vs 2.3%; P = .016), and a similar reduction in both asthma symptoms (ACQ6 0.7 vs 0.8; P = .623) and exacerbations (66.7% vs 66.7%; P = .349) at long-term follow-up when compared with those with a negative FeNOSuppT.
Conclusions:
Delivering FeNOSuppT aligned with digital monitoring is feasible within routine care. A positive FeNOSuppT was associated with lower rates of biologic initiation, with similar clinical outcomes.
Related Concept Videos
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
COPD: Management Using Bronchodilators and Corticosteroids
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...

