SIGH35 and end-expiratory occlusion test for assessing fluid responsiveness in critically ill patients undergoing
Antonio Messina1,2, Lorenzo Calabrò3, Francesco Benedetto4,5
1IRCCS Humanitas Research Hospital, Via Manzoni 56, 20089, Rozzano, Milan, Italy. antonio.messina@humanitas.it.
Background:
Assessing fluid responsiveness is problematic for critically ill patients with spontaneous breathing activity, such as during Pressure Support Ventilation (PSV), since spontaneous breathing activity physiologically affects heart-lung interplay. We compared the reliability of two hemodynamic tests in predicting fluid responsiveness in this clinical setting: SIGH35, based on a ventilator-generated sigh applied at 35 cmH2O for 4 s and the end-expiratory occlusion test (EEOT).
Methods:
Prospective study conducted in a general intensive care unit (ICU) and enrolling patients in PSV showing different inspiratory effort [assessed by airway occlusion pressure (P0.1)] and requiring volume expansion (VE). Hemodynamic variables were recorded by means of the MOSTCARE® system, patient received a VE using 4 ml/kg of crystalloids over 10 min and were considered responders if a cardiac output (CO) ≥ 10% was observed. The reliability of SIGH35 and EEOT in discriminating fluid responsiveness was assessed using receiver operating characteristic (ROC) curve approach and the area (AUC) under ROC curves was compared. For the EEOT, we considered the percent changes of CO between baseline the end of the test, while for the SIGH35, the percent changes of pulse pressure (PP) between baseline and the lowest value recorded after SIGH35 application.
Results:
Sixty ICU patients were enrolled, and 56 patients analysed. The AUC of PP changes after SIGH35 was 0.93 (0.84-0.99) [sensitivity of 93.1% (78.0-98.7%); specificity of 91.6 (73.0-98.9%)]; best threshold - 25% PP from baseline (grey zone - 15%/35%)]; and greater than the AUC of CO changes after EEOT [0.67 (0.52-0.81); sensitivity of 72.4% (54.3-85.3%) specificity of 70.3% (73.0-98.9%)]; best threshold 4% of CO increase from baseline (grey zone - 1%/10%)]. In the subgroup having a P0.1 < 1.5 cmH2O, the AUC of SIGH35 [0.98 (0.94-0.99)] and of EEOT [0.89 (0.72-0.99] were comparable (p = 0.26).
Conclusions:
In a selected ICU population undergoing PSV, SGH35 reliably predicted fluid responsiveness and performed better than the EEOT, which is, however, still reliable in the subgroup of ICU patients having a small extent of inspiratory efforts.
Related Concept Videos
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...
Pulmonary Cycle: Exhalation
Respiratory System Abnormal Finding II: Palpation and Auscultation
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Breathing
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...
Chronic Obstructive Pulmonary Disease
Smoking is a primary risk factor for COPD, with over 80% of patients having a history of it. Patients typically experience progressive dyspnea or labored breathing, frequent coughing, and recurrent pulmonary infections. Many eventually succumb to respiratory failure, characterized by...