Experimental determination of TNT equivalence values for binary energetic materials

Gracie May M James1, Rachel L Bauer1, Emily M Johnson1

  • 1Mining and Explosives Engineering Department, Missouri University of Science and Technology, 1400 North Bishop Ave, Rolla, MO, 65409, USA.

Scientific Reports
|May 4, 2025
PubMed
Summary

This study determined TNT equivalency for several energetic materials using plate dent, reaction velocity, and air blast tests. Results show varied performance, highlighting the need to match test types to material characteristics for accurate safety and performance evaluations.

Related Concept Videos

Atomic Emission Spectroscopy: Overview01:20

Atomic Emission Spectroscopy: Overview

Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
528
Nuclear Transmutation03:20

Nuclear Transmutation

Nuclear transmutation is the conversion of one nuclide into another. It can occur by the radioactive decay of a nucleus, or the reaction of a nucleus with another particle. The first manmade nucleus was produced in Ernest Rutherford’s laboratory in 1919 by a transmutation reaction, the bombardment of one type of nuclei with other nuclei or with neutrons. Rutherford bombarded nitrogen-14 atoms with high-speed α particles from a natural radioactive isotope of radium and observed...
17.2K
Constant Volume Calorimetry02:41

Constant Volume Calorimetry

Calorimeters are useful to determine the heat released or absorbed by a chemical reaction. Coffee cup calorimeters are designed to operate at constant (atmospheric) pressure and are convenient to measure heat flow (or enthalpy change) accompanying processes that occur in solution at constant pressure. A different type of calorimeter that operates at constant volume, colloquially known as a bomb calorimeter, is used to measure the energy produced by reactions that yield large amounts of heat and...
26.7K
Flame Photometry: Lab01:16

Flame Photometry: Lab

In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
173
Atomic Emission Spectroscopy: Lab01:29

Atomic Emission Spectroscopy: Lab

AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
124
Atomic Nuclei: Nuclear Spin State Population Distribution01:14

Atomic Nuclei: Nuclear Spin State Population Distribution

Near absolute zero temperatures, in the presence of a magnetic field, the majority of nuclei prefer the lower energy spin-up state to the higher energy spin-down state. As temperatures increase, the energy from thermal collisions distributes the spins more equally between the two states. The Boltzmann distribution equation gives the ratio of the number of spins predicted in the spin −½ (N−) and spin +½ (N+) states.
887