Related Experiment Video
Updated: May 8, 2025

Real Time Measurements of Membrane Protein:Receptor Interactions Using Surface Plasmon Resonance SPR
Published on: November 29, 2014
Reaction kinetics of membrane receptors: a spatial modeling approach
1Department of Mathematics, University of Utah, Salt Lake City, UT, 84112, USA.
None:
The interactions between diffusing molecules and membrane-bound receptors drive numerous cellular processes. In this work, we develop a spatial model of molecular interactions with membrane receptors by homogenizing the cell membrane and describing the evolution of both molecular diffusion and molecule-receptor interactions. By analyzing a resulting partial differential equation coupled to ordinary differential equations, we derive analytical expressions for the steady-state molecular influx rate in four prototypical interaction scenarios: Michaelis-Menten kinetics, Substrate Competition, Competitive Inhibition, and Uncompetitive Inhibition. For each scenario, we show how to modify the classical well-mixed reaction rate theory to resolve spatial features inherent to receptors bound to cell membranes. We find that naive well-mixed calculations significantly overestimate reaction rates in certain biophysical parameter regimes.
More Related Videos
15:13High-resolution Spatiotemporal Analysis of Receptor Dynamics by Single-molecule Fluorescence Microscopy
Published on: July 25, 2014
07:31Author Spotlight: Advancing Cell Membrane Biophysics - Exploring Interactions and Challenges Through Experimental and Computational Approaches
Published on: September 1, 2023
Related Concept Videos
The Two-State Receptor Model
The binding affinity of a drug determines its interaction with...
Protein Diffusion in the Membrane
Quantitative Aspects of Drug-Receptor Interaction
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models