Related Experiment Video
Updated: May 8, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Feasibility of individual dosimetry using RT-PHITS for patients with SPECT/CT imaging after 177Lu-DOTATATE peptide
Kenta Miwa1, Ryo Kakino2, Tatsuhiko Sato3,4
1Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, 10-6 Sakaemachi, Fukushima, 960-8516, Japan. kmiwa@fmu.ac.jp.
Abstract:
A radiotherapy package based on the Particle and Heavy Ion Transport code System (RT-PHITS) can calculate internal 3-dimensional dose distribution from SPECT/CT images of individual patients coupled with Monte Carlo radiation transport simulation. This study aims to determine the feasibility of individual dosimetry using RT-PHITS for patients after 177Lu-DOTATATE peptide receptor radionuclide therapy (PRRT). We acquired SPECT/CT images from two patients from the 177Lu SNMMI Dosimetry Challenge (patients A and B) and one from our institute (patient C) at various time points. The images were converted to source/geometry information in the PHITS input format using RT-PHITS. The 3D dose-rate distribution in each patient was calculated using Monte Carlo radiation transport simulation. The output data from the PHITS simulation were converted to DICOM RT-dose format and analyzed using 3D Slicer to identify dose rates in lesions and organs at risk. The time variations of the calculated dose rates were linearly interpolated, considering the physical decay constant. The absorbed dose was evaluated as the integration of the time variation of the dose rate. Agreements between the absorbed doses obtained from RT-PHITS and 177Lu Dosimetry Challenge Task 4 were generally satisfactory (< 20%), although discrepancies were noted in some normal organs of patient A. This was likely due to difficulties in estimating the tail of the dose rate curve after the last imaging time point. The EQD2 was slightly, but not significantly increased compared with the absorbed dose in patient C. Individual dosimetry using RT-PHITS is feasible for assessing the effects of 177Lu-DOTATATE PRRT.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
08:34Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...