Strong field gradients enable NMR-based diffusion measurements for K+, Mg2+, Cl-, and SO42- ions in biomolecular

Tianzhi Wang1, Daniel Arcos2, F David Doty2

  • 1Department of Biochemistry & Molecular Biology, Sealy Center for Structural Biology & Molecular Biophysics, University of Texas Medical Branch, Galveston, TX 77555-1068, USA.

Related Concept Videos

Atomic Nuclei: Nuclear Spin State Population Distribution01:14

Atomic Nuclei: Nuclear Spin State Population Distribution

Near absolute zero temperatures, in the presence of a magnetic field, the majority of nuclei prefer the lower energy spin-up state to the higher energy spin-down state. As temperatures increase, the energy from thermal collisions distributes the spins more equally between the two states. The Boltzmann distribution equation gives the ratio of the number of spins predicted in the spin −½ (N−) and spin +½ (N+) states.
891
Atomic Nuclei: Nuclear Relaxation Processes01:23

Atomic Nuclei: Nuclear Relaxation Processes

In the absence of an external magnetic field, nuclear spin states are degenerate and randomly oriented. When a magnetic field is applied, the spins begin to precess and orient themselves along (lower energy) or against (higher energy) the direction of the field. At equilibrium, a slight excess population of spins exists in the lower energy state. Because the direction of the magnetic field is fixed as the z-axis,  the precessing magnetic moments are randomly oriented around the z-axis.
581
¹H NMR: Interpreting Distorted and Overlapping Signals01:02

¹H NMR: Interpreting Distorted and Overlapping Signals

Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
925
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
590