Comparative study of heuristic algorithms for coordination of industrial over current relays with nonstandard
Ekta Gairola1, Mahiraj Singh Rawat1, Padmanabh Thakur2
1Department of Electrical Engineering, National Institute of Technology, Uttarakhand, 246174, Srinagar Garhwal, India.
Abstract:
The traditional methods for over-current relay coordination (OCR) may not be adequate to ensure consistent and dependable operation of microgrid (MG), in its various operating modes. In this work, optimal TMS settings for OCRs in a microgrid model have been obtained using SCA & mod WOA. OCRs with non-standard characteristics have been used as it is less investigated in literature. The results obtained are compared with those in standard literature using GA. It is found that the total time of operation (top) of relays reduces to 5.1676 s for operating mode 1(OM1), for operating mode 2 (OM2) top value reduces to 14.8376 s and the top reduces to 13.9448 s for operating mode 3 (OM3) by using SCA as compared to the values in standard literature considered here. The top of all individual relays in all the OMs is reduced in case of SCA as compared to the standard literature. At the same time the CTI for all relay pairs is maintained greater than 0.3 s, which is essential for relay coordination. The results using mod WOA are not satisfactory as far as the reduction in top is concerned for various operating modes, though the OCR coordination is achieved. SCA & mod WOA coding in MATLAB is used to optimize time multiplying setting (TMS) for OCR coordination. The International Electrotechnical Commission (IEC) microgrid benchmark system is implemented in DIgSILENT Powerfactory 2018 software to investigate the various operating modes of microgrid.
More Related Videos
04:35Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
Published on: July 5, 2024
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Overcurrent Relays
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Differential Relays
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Pilot and Numeric Relaying