Related Experiment Video
Updated: May 13, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
A flexible multi-agent system for managing demand and variability in hybrid energy systems for rural communities
Ehab S Ali1, M H Elkholy2,3, Tomonobu Senjyu4
1Department of Electrical and Electronics Engineering, College of Engineering and Computer Science, Jazan University, 45142, Jizan, Saudi Arabia. esalama@jazanu.edu.sa.
Abstract:
Access to reliable, economical, and sustainable energy is a critical challenge in remote communities where infrastructure constraints and unreliability of renewable energy sources (RESs) complicate the possibility of having a stable supply. This study is motivated by the urgent need for intelligent, adaptive energy management systems that can ensure the reliability of the supply while maximizing the use of RESs. To meet this need, an adaptive and scalable multi-agent system (MAS) framework for hybrid energy systems can be employed. The system includes electric vehicle batteries (EVBs), hydrogen energy storage systems (HESSs), and battery energy storage systems (BESSs) and wind turbines (WTs) and PV. A hybrid backup architecture for energy supply continuity in low availability of RESs, in addition to vehicle-to-grid (V2G) functionality enabling EVBs to support grid stability. The MAS is evaluated under four scenarios: PV-WTs-BESSs, PV-WTs-BESSs-EVBs, PV-WTs-BESSs-HESSs, and PV-WTs-BESSs-EVBs-HESSs. Scenario 4 attains the lowest operating cost of $10,688.06, a reduction of 0.91% from scenario 1, in a 25 kW peak load microgrid. The artificial gorilla troops optimizer optimizes the real-time energy dispatch by learning to adjust to changing system conditions. Simulation results confirm that the proposed MAS improves cost-effectiveness, energy stability, and sustainability in constrained settings.
More Related Videos
Related Concept Videos
Distributed Loads: Problem Solving
Secondary Distribution
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
Distribution Reliability and Automation
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Multi-input and Multi-variable systems
In the absence...
Distributed Loads
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...

