Intravascular Ultrasound Image-Based Finite Element Modeling Approach for Quantifying In Vivo Mechanical Properties of Human Coronary Artery
Published on: December 6, 2024
Focal comparison of experimental and finite element derived strain fields in a 3D IVUS-based computational model of
Caleb C Berggren1, Y F Jack Wang2, Amanda M F Sigler1
1Department of Biomedical Engineering, University of Utah, Salt Lake City, UT 84112, USA.
Abstract:
Arterial tissues are subjected to mechanical loads that influence biological mechanisms in health and disease. Motivated by these observations, computational models to predict the vascular mechanical environment are increasingly being developed and applied. However, few computational vascular biomechanics studies are evaluated for accuracy. This study aimed to compare the transmural strain fields in healthy vascular tissue under physiologic loading between 3D intravascular ultrasound (IVUS)-based finite element (FE) models and image-based experimental measurements. IVUS image data were captured along a ∼ 15 mm segment in porcine carotid arteries (n = 3) in the reference configuration (∼10 mmHg) and at five axial positions under varied pressure loads. FE models were constructed from the full-length segment IVUS data, and model-predicted strains were determined using reported soft and stiff material properties for porcine tissue. Experimental strains were determined at each axial slice across the applied loads using a deformable image registration technique (Hyperelastic Warping). Both FE-predicted and experimental deformations exhibited non-linear behavior under loading, as observed in the material response curves. Following Warping parameter selection, results demonstrated that FE-predicted transmural strains with soft and stiff material properties bounded the experimentally-derived data at systolic pressures; however, sample variability was observed. At systolic pressure, Warping-derived and FE-predicted transmural strains showed good agreement, as RMSE values were < 0.09 and differences < 0.08. In conclusion, this study presents an experimental framework to assess accuracy in IVUS-based FE models, and results indicate that the computational framework can predict realistic deformations of arterial tissue; however, the accuracy strongly depends on tissue-specific material properties.
More Related Videos
Related Concept Videos
True Stress and True Strain
In contrast, true stress offers a more precise portrayal. It is computed by dividing the...
Normal Strain under Axial Loading
Three-Dimensional Analysis of Strain
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Transformation of Plane Strain
Under plane strain conditions, typical for members where one dimension significantly exceeds the others, deformations and resultant strains are...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....