Multi-Scale Modification of Metallic Implants With Pore Gradients, Polyelectrolytes and Their Indirect Monitoring In vivo
Published on: July 1, 2013
Degradable poly-lactic-co-glycolic acid and non-degradable polymer implants result in similar fracture healing at
Anna N Smith1, Kathryn S Strand1, Trent J Levy1
1McKay Orthopaedic Research Lab, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
Background:
Although rigid interfragmentary fixation is required for fracture repair, overly stiff implants are known to cause stress shielding which ultimately inhibits healing. While gradual dynamization of the fracture site both accelerates and improves osteogenesis, this approach requires external fixators or secondary surgeries. This study leverages biodegradable implants as mechanisms of gradual, passive dynamization during fracture healing.
Methods:
Using a rat femoral osteotomy model, additively manufactured poly-lactic-co-glycolic acid implants were compared to geometrically matched non-degradable biocompatible resin devices. Bone healing was assessed at 3 and 6 weeks via micro-computed tomography, histology, and mechanical testing. Implant degradation kinetics were assessed through testing of plates that were used in the rat model and with an unloaded in vitro degradation model.
Findings:
Quantitative bone measures made with micro-computed tomography, histology, and mechanical testing of the healing femora revealed no differences between degradable and non-degradable implants at 3 or 6 weeks. Degradable implants caused significant increases in bone volume to total volume mean density (p < 0.0001) and callus to cortical volume (p < 0.05) ratios between 3 and 6 weeks. Poly-lactic-co-glycolic acid devices were significantly stiffer than resin at week 0, but the two groups were equivalent by week 6 due to in vivo degradation. In vivo ambulatory loading caused significant losses of degradable implant stiffness at both 3 (p < 0.05) and 6 (p < 0.01) weeks, but this was not observed in the unloaded in vitro model.
Interpretation:
The results from this early timepoint study demonstrate the feasibility of passive, internal fracture dynamization driven by implant material mechanics.
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...