Related Experiment Video
Updated: May 15, 2025

Standardized Hemorrhagic Shock Induction Guided by Cerebral Oximetry and Extended Hemodynamic Monitoring in Pigs
Published on: May 21, 2019
Intraoperative Assessment of Cerebral Autoregulation With Cerebral Oximetry Index in Neonates Undergoing Cardiac
Stefano Pezzato1, Rathinaswamy B Govindan2, Erta Beqiri3
1Neonatal and Pediatric Intensive Care Unit, IRCCS Istituto Giannina Gaslini, Genova, Italy; Division of Cardiac Surgery, Children's National Hospital, Washington, DC.
Objective:
To investigate cerebral autoregulation impairment during neonatal cardiac surgery.
Design:
A retrospective observational study.
Setting:
Single-center, university teaching children's hospital.
Participants:
Neonates undergoing surgery for critical congenital heart defects.
Interventions:
Calculation of the cerebral oximetry index (COx) and COx-derived parameters was performed by processing signals from intraoperative routine monitoring.
Measurements And Main Results:
High-resolution intraoperative data were retrieved from a cohort of 16 term neonates. COx was calculated as the linear correlation between mean arterial blood pressure and cerebral oximetry in a 5-minute moving time window. Averaged COx values were obtained before, during, and after cardiopulmonary bypass (CPB), and comparisons were made using the Kruskal-Wallis test. A linear mixed-effects model was used to examine the associations between COx and other intraoperative physiological variables. Intraoperative limits of autoregulation for a COx cut-off of 0.3 were identified by combining data from the entire cohort. The median COx was 0.02 (interquartile range [IQR], -0.08 to 0.13) pre-CPB, 0.34 (IQR, 0.18-0.43) during CPB, and 0.26 (IQR, 0.05-0.38) post-CPB. Intraoperative evolution of COx was linearly associated with changes in cerebral oximetry, pO2, and core temperature but not with mean arterial pressure and pCO2. For the entire cohort, the intraoperative lower and upper limits of autoregulation were 35 mmHg and 59 mmHg, respectively.
Conclusions:
Cerebral autoregulation was impaired during CPB and remained altered after separation from bypass. Real-time monitoring of the COx may be useful for identifying autoregulation disturbances and providing a more individualized approach to CPB management.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...

