Related Experiment Video
Updated: May 17, 2025

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
Research on Intrusion Detection Method Based on Transformer and CNN-BiLSTM in Internet of Things
Chunhui Zhang1, Jian Li1, Naile Wang1
1School of Cyberspace Security, Beijing University of Post and Telecommunications, Beijing 100876, China.
Abstract:
With the widespread deployment of Internet of Things (IoT) devices, their complex network environments and open communication modes have made them prime targets for cyberattacks. Traditional Intrusion Detection Systems (IDS) face challenges in handling complex attack types, data imbalance, and feature extraction difficulties in IoT environments. Accurately detecting abnormal traffic in IoT has become increasingly critical. To address the limitation of single models in comprehensively capturing the diverse features of IoT traffic, this paper proposes a hybrid model based on CNN-BiLSTM-Transformer, which better handles complex features and long-sequence dependencies in intrusion detection. To address the issue of data class imbalance, the Borderline-SMOTE method is introduced to enhance the model's ability to recognize minority class attack samples. To tackle the problem of redundant features in the original dataset, a comprehensive feature selection strategy combining XGBoost, Chi-square (Chi2), and Mutual Information is adopted to ensure the model focuses on the most discriminative features. Experimental validation demonstrates that the proposed method achieves 99.80% accuracy on the CIC-IDS 2017 dataset and 97.95% accuracy on the BoT-IoT dataset, significantly outperforming traditional intrusion detection methods, proving its efficiency and accuracy in detecting abnormal traffic in IoT environments.
Related Concept Videos
Instrument Transformers
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Types Of Transformers
If the ratio of the number of turns in the secondary winding to that of the primary winding is greater than one, then the transformer is said to be a step-up transformer. In a step-up transformer, the voltage at the secondary winding is greater than the voltage applied at the primary winding.
However, if this ratio is less than one, the transformer is said to be a step-down...
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...

