Related Experiment Video
Updated: May 16, 2025

The Effect of Ultraviolet Radiation on the Chemical Bath Deposition of Bisthiourea Cadmium Chloride Crystals and the Subsequent CdS Obtention
Published on: August 30, 2018
Direct Spectrophotometric Method for Determination of Cadmium (II) Ions Using Bis-Thiosemicarbazone
Sulafa Nassar1, Gharam I Mohammed1, Thoraya A Farghaly2
1Chemistry Department, Faculty of Science, Umm Al-Qura University, Makkah, Saudi Arabia.
Abstract:
A novel and simple study outlines the advancement of a straightforward and precise spectrophotometric technique for the determination of Cd (II) ions. This method offers a notable benefit as it is a straightforward procedure that does not require additional purification or concentration of the solvent. The concentration of Cd (II) ions was determined in the presence of bis(indoline-2, 3-dione) thiosemicarbazone (L) at a pH of 12 using Briton-Robinson Buffer. The concentration range for Cd (II) ions in the method follows Beer's law and is between (1.8-17.8) × 10-5 mol L-1. The limit of detection is 0.245 μg mL-1(2.2 μmol L-1) and the limit of quantification is 0.817 μg mL-1 (7.3 μmol L-1). The molar ratio between L and Cd (II) ions was 1:2, ensuring the development of a metal complex. The applied method offers numerous benefits, including its simplicity, affordability, convenience of use, quick detection, minimal use of ligands, and high sensitivity. The sensitivity of the analytical approach was verified by carefully selecting appropriate experimental conditions. Additional insights into the composition and arrangement of the complex produced in a solution containing Cd (II) ions and the ligand (L) have been obtained by isolating and studying the solid complex L-Cd. The solid complex, L-Cd, was determined using analytical methods including elemental analysis, UV-Vis spectra, spectral mass, and thermal analysis.
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
Qualitative Analysis
For instance, group IV...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...

