Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Investigating the accuracy of Apple Watch VO2 max measurements: A validation study
Rory Lambe1,2, Ben O'Grady1,2, Maximus Baldwin1,2,3
1School of Public Health, Physiotherapy and Sports Science, University College Dublin, Dublin 4, Ireland.
Abstract:
VO2 max is a measure of cardiorespiratory fitness and a key indicator of overall health. It is predictive of cardiovascular events and shows a strong inverse association with all-cause mortality. Increased cardiorespiratory fitness is associated with reductions in coronary artery disease, diabetes and cancer. Apple Watch offers a less resource-intensive and more feasible alternative to the gold standard assessment for VO2 max, indirect calorimetry, but the accuracy of its measurements remains uncertain. This study aimed to assess the validity of VO2 max estimates from Apple Watch in comparison to indirect calorimetry. Thirty participants wore an Apple Watch for 5-10 days to generate a VO2 max estimate. Subsequently, they underwent a maximal exercise treadmill test in accordance with the modified Åstrand protocol. The agreement between measurements from Apple Watch and indirect calorimetry was assessed using Bland-Altman analysis, mean absolute percentage error (MAPE), and mean absolute error (MAE). Overall, Apple Watch underestimated VO2 max, with a mean difference of 6.07 mL/kg/min (95% CI 3.77-8.38). Limits of agreement indicated variability between measurement methods (lower -6.11 mL/kg/min; upper 18.26 mL/kg/min). MAPE was calculated as 13.31% (95% CI 10.01-16.61), and MAE was 6.92 mL/kg/min (95% CI 4.89-8.94). These findings indicate that Apple Watch VO2 max estimates require further refinement prior to clinical implementation. However, further consideration of Apple Watch as an alternative to conventional VO2 max prediction from submaximal exercise is warranted, given its practical utility.
Related Concept Videos
Measurement of Blood Pressure
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of blood pressure in brachial artery(two-step method)
Errors occurring during blood pressure monitoring
Several factors...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...