Related Experiment Video
Updated: May 17, 2025

08:25
Contact Hypersensitivity as a Murine Model of Allergic Contact Dermatitis
Published on: September 26, 2022
2.5K
Thresholds for Contact Allergy to a Rubber Accelerator: TETD-Determined by Serial Dilution Patch Testing and a
Christoffer Kursawe Larsen1,2,3, Jeanne D Johansen1,2,3, Claus Zachariae1,2,3
1National Allergy Research Centre, Department of Dermatology and Allergy, Herlev and Gentofte Hospital, Hellerup, Denmark.
Contact Dermatitis
|May 16, 2025
Summary
Rubber accelerators like tetraethylthiuram disulfide (TETD) in gloves can cause allergic contact dermatitis. Even low doses of TETD, as low as 0.75 μg/cm², may trigger reactions in sensitive individuals.
Area of Science:
- Dermatology
- Toxicology
- Occupational Health
Background:
- Rubber accelerators, such as tetraethylthiuram disulfide (TETD), are common components in rubber gloves.
- These accelerators can cause allergic contact dermatitis (ACD) in susceptible individuals.
- Identifying the threshold for ACD induction is crucial for preventing occupational allergies.
Purpose of the Study:
- To determine the specific doses of TETD that induce allergic contact dermatitis.
- To compare the efficacy of patch testing versus a repeated occluded application test in simulating glove use for ACD assessment.
- To establish a dose-response relationship for TETD-induced ACD.
Main Methods:
- A multicenter study involving eight patients with known TETD allergy and eight controls.
- Patch testing with serial dilutions of TETD (1% down to 0.0041%).
- Repeated occluded application tests simulating glove use with TETD concentrations of 1%, 0.33%, and 0.11%.
Main Results:
- Three out of eight patients reacted to the lowest TETD dose (0.0041%, 1.6 μg/cm²) in patch tests.
- All patients exhibited reactions to all tested TETD concentrations in the repeated occluded application test.
- The estimated dose of TETD eliciting ACD in 10% of patients (ED10) was 0.75 μg/cm² via patch testing.
Conclusions:
- A TETD content of 0.75 μg/cm² in rubber gloves may be sufficient to induce allergic contact dermatitis.
- The repeated occluded application test is a valuable model for future studies on contact allergy to rubber accelerators.
- This study provides critical data for setting safe limits for TETD in consumer products to prevent allergic reactions.
Related Concept Videos
Pulmonary Tuberculosis III
271
Tuberculosis (TB) is a contagious infection primarily affecting the lung parenchyma but which can also affect other body parts. TB can be classified based on disease development, presentation, and the affected anatomical site.
The first classification is based on the development of the disease, and it includes the following categories:
The first classification is based on the development of the disease, and it includes the following categories:
271
Allergic Reactions
27.2K
Overview
27.2K
Pulmonary Tuberculosis IV
124
Tuberculosis, more commonly referred to as TB, is an infectious disease stemming from Mycobacterium tuberculosis. While it primarily impacts the lungs, TB can also affect other body areas. Given its severity and global impact, timely and accurate diagnosis is crucial for controlling its spread and improving patient outcomes.
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
124

