Related Experiment Video
Updated: May 1, 2026

Automated Midline Shift and Intracranial Pressure Estimation based on Brain CT Images
Published on: April 13, 2013
CALIMAR-GAN: An unpaired mask-guided attention network for metal artifact reduction in CT scans
Roberto Maria Scardigno1, Antonio Brunetti1, Pietro Maria Marvulli1
1Department of Electrical and Information Engineering (DEI), Polytechnic University of Bari, Bari, 70126, Italy.
Abstract:
High-quality computed tomography (CT) scans are essential for accurate diagnostic and therapeutic decisions, but the presence of metal objects within the body can produce distortions that lower image quality. Deep learning (DL) approaches using image-to-image translation for metal artifact reduction (MAR) show promise over traditional methods but often introduce secondary artifacts. Additionally, most rely on paired simulated data due to limited availability of real paired clinical data, restricting evaluation on clinical scans to qualitative analysis. This work presents CALIMAR-GAN, a generative adversarial network (GAN) model that employs a guided attention mechanism and the linear interpolation algorithm to reduce artifacts using unpaired simulated and clinical data for targeted artifact reduction. Quantitative evaluations on simulated images demonstrated superior performance, achieving a PSNR of 31.7, SSIM of 0.877, and Fréchet inception distance (FID) of 22.1, outperforming state-of-the-art methods. On real clinical images, CALIMAR-GAN achieved the lowest FID (32.7), validated as a valuable complement to qualitative assessments through correlation with pixel-based metrics (r=-0.797 with PSNR, p<0.01; r=-0.767 with MS-SSIM, p<0.01). This work advances DL-based artifact reduction into clinical practice with high-fidelity reconstructions that enhance diagnostic accuracy and therapeutic outcomes. Code is available at https://github.com/roberto722/calimar-gan.
More Related Videos
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
08:19Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System IV: CMRI