Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Capillary Electrophoresis: Instrumentation01:20

Capillary Electrophoresis: Instrumentation

162
Capillary electrophoresis instrumentation typically consists of several key components. A high-voltage power supply generates the electric field necessary for the separation by connecting to an anode (the positively charged electrode) and a cathode (the negatively charged electrode) located in buffer reservoirs at each end of the capillary tube. The system includes a sample vial, a fused silica capillary tube coated with polyimide for mechanical strength through which the sample components...
162
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

361
In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...
361
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

309
Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
309
Electrophoresis: Overview01:20

Electrophoresis: Overview

774
Electrophoresis is a powerful analytical separation technique that relies on the differential migration of charged species when subjected to an electric field. The core strength of electrophoresis lies in its ability to separate high-molecular-weight species in complex mixtures. It has found widespread use in biochemistry, molecular biology, and analytical chemistry, allowing the separation of compounds like amino acids, nucleotides, carbohydrates, and proteins with excellent resolution.
There...
774
Gas Chromatography: Sample Injection Systems01:08

Gas Chromatography: Sample Injection Systems

324
In gas chromatography, the sample is introduced as a vapor plug into the carrier gas stream for high efficiency and resolution. A microsyringe injects the sample solution into a heated sample port, vaporizing it and mixing it with the carrier gas. This process is important to ensure the sample is properly prepared for analysis. Thermally sensitive samples can be injected directly into the column and volatilized by slowly increasing the column temperature.
Two primary injection methods are used...
324

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Nanocarriers engineering for efficient NSUN2 silencing and immune responsive therapy in metastatic colorectal cancer.

Materials today. Bio·2026
Same author

Multiplex CD30/Carbonic Anhydrase IX Lateral Flow Assay for Rapid Triage of Suspected BIA-ALCL in Peri-implant Seroma Fluid.

Aesthetic surgery journal·2026
Same author

Matrix-matched low-concentration internal quality control detects high-sensitivity cardiac troponin T errors missed by commercial controls.

Talanta·2026
Same author

Ameliorative Effects of an Antioxidant and Anti-Inflammatory Limosilactobacillus fermentum TG017 on DSS-Induced Ulcerative Colitis in Mice.

Probiotics and antimicrobial proteins·2026
Same author

Dual-targeted nano-inhibitors of pyroptosis for synergistic therapy of traumatic brain injury.

Journal of controlled release : official journal of the Controlled Release Society·2026
Same author

Neutrophil Extracellular Traps in Systemic Lupus Erythematosus: Pathogenic Mechanisms, Crosstalk with Oxidative Stress, and Antioxidant Therapeutic Potential.

Antioxidants (Basel, Switzerland)·2026

Related Experiment Video

Updated: May 20, 2025

Fast Enzymatic Processing of Proteins for MS Detection with a Flow-through Microreactor
09:49

Fast Enzymatic Processing of Proteins for MS Detection with a Flow-through Microreactor

Published on: April 6, 2016

7.9K

Closed-loop peristaltic micro-pump for flow-through sample injection in capillary electrophoresis.

Jin Zhang1, Hui Zeng1, Wenshan Liang1

  • 1School of Life and Environmental Sciences, Guangxi Key Laboratory of Automatic Detecting Technology and Instruments, Guilin University of Electronic Technology, Guilin, Guangxi, 541004, China.

Talanta
|May 17, 2025
PubMed
Summary

A new closed-loop peristaltic micro-pump (PMP) significantly improves precision in capillary electrophoresis (CE) systems for environmental water monitoring. This cost-effective PMP enhances flow-through injection, enabling reliable detection of ions and nutrients in field applications.

Keywords:
Capillary electrophoresisEnvironmental monitoringFlow-through injectionIon detectionPeristaltic micro-pump

More Related Videos

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

Published on: November 23, 2015

13.7K
Miniaturized Sample Preparation for Transmission Electron Microscopy
09:04

Miniaturized Sample Preparation for Transmission Electron Microscopy

Published on: July 27, 2018

19.5K

Related Experiment Videos

Last Updated: May 20, 2025

Fast Enzymatic Processing of Proteins for MS Detection with a Flow-through Microreactor
09:49

Fast Enzymatic Processing of Proteins for MS Detection with a Flow-through Microreactor

Published on: April 6, 2016

7.9K
A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
11:32

A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice

Published on: November 23, 2015

13.7K
Miniaturized Sample Preparation for Transmission Electron Microscopy
09:04

Miniaturized Sample Preparation for Transmission Electron Microscopy

Published on: July 27, 2018

19.5K

Area of Science:

  • Analytical Chemistry
  • Environmental Science
  • Instrumentation

Background:

  • Capillary electrophoresis (CE) is valuable for environmental monitoring, but requires precise sample injection.
  • Miniaturized, low-cost instruments are needed for distributed field applications, teaching, and citizen science.
  • Peristaltic micro-pumps (PMPs) offer a compact and energy-efficient solution for automated injection in miniaturized CE.

Purpose of the Study:

  • To develop and apply a closed-loop peristaltic micro-pump (PMP) integrated into a capillary electrophoresis (CE) system.
  • To enhance the precision and analytical performance of flow-through injection in CE.
  • To provide a cost-effective tool for on-site environmental water quality monitoring.

Main Methods:

  • Integrated a Hall sensor into a PMP for closed-loop rotor position monitoring and stable operation.
  • Developed a CE system incorporating the modified PMP for automated flow-through injection.
  • Applied the system to detect common cations and anions, and analyze total nitrogen and phosphorus in water samples.

Main Results:

  • The closed-loop PMP achieved a pressure relative standard deviation (RSD) of 0.7%, a threefold improvement over other feedback methods.
  • CE system demonstrated high precision with injection RSDs below 4.0% for ions and reliable calibration (R² ≥ 0.994).
  • Detection limits for ions ranged from 0.9 to 3.6 μM, with peak height RSDs in tap water between 1.1% and 7.7%.

Conclusions:

  • The modified CE system with a closed-loop PMP significantly enhances injection precision and analytical performance.
  • The system offers a versatile and reliable platform for environmental ion and nutrient detection.