Related Experiment Video
Updated: May 20, 2025

Direct Detection of Isolevuglandins in Tissues Using a D11 scFv-Alkaline Phosphatase Fusion Protein and Immunofluorescence
Published on: July 5, 2021
Electrochemiluminescence Biosensor Based on an Efficient Antifouling Cell Membrane Hydrogel for the Direct Detection
Qiongwei Wu1, Zhengjun Dong1, Fan Geng1
1Key Laboratory of Optic-electric Sensing and Analytical Chemistry for Life Science, Ministry of Education, Shandong Key Laboratory of Biochemical Analysis, Key Laboratory of Analytical Chemistry for Life Science in Universities of Shandong, College of Chemistry and Molecular Engineering, Qingdao University of Science and Technology, Qingdao 266042, P. R. China.
Abstract:
Electrochemiluminescence (ECL) biosensors are an ideal choice for the real-time and sensitive detection of biomarkers. However, there are many interfering biomolecules in human serum or cell lysate that can affect the ECL signal through nonspecific interface adsorption. To solve this issue, an efficient ECL antifouling biosensor based on a red blood cell membrane (RBCM) hydrogel was developed for the direct detection of alkaline phosphatase (ALP) in human serum and cell lysate. Among them, the RBCM hydrogel was prepared by embedding the purified RBCM vesicles into [1,2-distearoyl-sn-glycerol-3-phosphoethanolamine]-[polyethylene]-[acrylamide] (DSPE-PEG-AM), which endowed the antifouling interface with high stability and biocompatibility. Meanwhile, compared to RBCM, the constructed RBCM hydrogel improved the electron transfer rate of the antifouling interface. Furthermore, luminescent copper nanosheets (Cu NSs) and quencher MnO2 NSs were encapsulated in the RBCM hydrogel, which greatly reduced the distance between Cu NSs and MnO2 NSs, thereby effectively improving the signal quenching efficiency. In the presence of ALP, l-ascorbic acid 2-phosphate trisodium salt was hydrolyzed to ascorbic acid, thus disrupting the structure of MnO2 NSs to restore the ECL signal. Based on the above sensing strategies, the constructed ECL biosensor achieved an ultrasensitive detection of ALP with a wide linear range (10-5 to 104 U·L-1) and a detection limit as low as 3.4 × 10-6 U·L-1 (3δ/k), demonstrating potential application value in clinical diagnosis.
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Photoluminescence: Applications

