Related Experiment Video
Updated: May 20, 2025

Therapy Interventions for Upper Limb Amputees Undergoing Selective Nerve Transfers
Published on: October 29, 2021
A Shortened Upper Extremity Functional Capacity Evaluation for Patients with Complaints of Hand, Wrist, Forearm, and
Redmar J Berduszek1, Rienk Dekker2, Corry K van der Sluis2
1Department of Rehabilitation Medicine, University Medical Center Groningen, University of Groningen, PO Box 30.001, 9700 RB, Groningen, The Netherlands. r.j.berduszek@umcg.nl.
Purpose:
Upper extremity functional capacity evaluation (UE-FCE) contains tests covering aspects of upper extremity functioning. UE-FCE tests usually consist of multiple repeated trials. Shortened UE-FCEs with less trials per test have been proposed but never tested in patients. The aims of this study were (1) to compose a shortened UE-FCE (fewer trials per test) and (2) to assess construct validity and test-retest reliability when applied in patients with nontraumatic musculoskeletal complaints of the hand, wrist, forearm, and elbow.
Methods:
Participants performed a UE-FCE, with original full-length tests, twice (1 to 3 weeks apart). A shortened UE-FCE, with fewer trials per test, was composed based on the agreement (ICC ≥ 0.90) between shortened and original UE-FCE tests. Consequently, construct validity and test-retest reliability of the shortened UE-FCE tests were assessed.
Results:
UE-FCEs were performed by 45 participants. The proposed shortened UE-FCE included one-trial tests for hand grip and finger strength (instead of three-trial tests), two-trial tests for fingertip and hand/forearm dexterity (instead of three-trial and four-trial tests, respectively). Overhead lifting and working tests were already one-trial tests and remain unchanged. Construct validity was demonstrated for hand grip strength of the left hand, overhead lifting, and overhead working, but not for hand grip strength of the right hand, finger strength, fingertip dexterity and hand and forearm dexterity. Test-retest reliability was above 0.70 for all tests, except for fingertip dexterity of the dominant hand (0.59).
Conclusion:
The shortened UE-FCE with fewer trials per test agreed strongly with the original UE-FCE. Using the shortened UE-FCE could save 18 min. Construct validity differed per UE-FCE test. Test-retest reliability was sufficient for all UE-FCE tests except fingertip dexterity of the dominant hand.
More Related Videos
05:28Author Spotlight: Enhancing Upper Limb Rehabilitation in Stroke Patients Through Advanced Robotic and Neuromodulation Technologies
Published on: October 11, 2024
06:25Capturing Representative Hand Use at Home Using Egocentric Video in Individuals with Upper Limb Impairment
Published on: December 23, 2020
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Bones of the Upper Limb: Humerus
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi...
Spinal Nerves: Plexus I
The Cervical Plexus