Related Experiment Video
Updated: Jun 14, 2025

Quantifying Arms and Legs Contributions during Repetitive Electrically-Assisted Sit-To-Stand Exercise in Paraplegics: A Pilot Study
Published on: November 11, 2022
Validity, Test-Retest Reliability, and Learning Effect on the 1-Minute Sit-To-Stand Test in Individuals With Heart
Ngoc-Minh Nguyen1, Hien Thi Le2, Bich-Ly Thi Ngo3
1Department of Rehabilitation, Faculty of Nursing and Medical Technology, University of Medicine and Pharmacy at Ho Chi Minh City, Ho Chi Minh City, Vietnam; Institut de Recherche Experimental et Clinique (IREC), Pneumology, ENT and Dermatology Pole (LUNS), Université Catholique de Louvain (UCLouvain), Brussels, Belgium.
Objective:
To evaluate the reliability, the minimally important difference (MID), and the learning effect of the 1-minute sit-to-stand test (1STST) in assessing functional exercise capacity in patients with heart failure (HF).
Design:
A cross-sectional study.
Setting:
Two hospitals.
Participants:
Patients with an HF (N=47) diagnosis by a cardiologist following the 2021 European Society of Cardiology HF guideline. Most participants were men (60%). Most participants had a normal body mass index (62%). All participants were classified as having New York Heart Association Functional Class II or III.
Interventions:
Not applicable.
Main Outcome Measures:
Each patient performed a 6-minute walk test (6MWT) and 2 1STSTs on 2 occasions spaced 1 month apart. Test-retest reliability between occasions was evaluated using the intraclass correlation coefficient (ICC), Bland-Altman plot analysis, and linear regression. The MID was determined using a distribution-based method. To assess the learning effect, we conducted a paired t test comparing the 2 1STSTs on each occasion, and the magnitude of the learning effect was quantified using Cohen's d. The correlation between the 1STST and 6MWT was performed to confirm validity.
Results:
The 1STST showed good test-retest reliability (ICC=0.98, P<.001) with good agreement between the 2 measurements, without proportional bias (P>.05). The MID was 1.1 repetitions. A learning effect of the 1STST was observed (P<.001) with a large effect size when repeated a month later (Cohen's d>0.8). The 1STST strongly correlated with the 6MWT (r=0.74, P=.01).
Conclusions:
The 1STST is a valid and reliable measure of functional exercise capacity in patients with HF. Because of the learning effect, this study recommended performing 2 trials to capture the true value.