A noncontact vital sign sensor demonstrating a strong correlation with an electrocardiogram electrode and a CO2
Tatsuya Nagano1, Nobuyuki Yamamoto2, Sae Shinomiya3
1Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, 7-5-1 Kusunoki-cho, Chuo-ku, Kobe, Hyogo, 650-0017, Japan. tnagano@med.kobe-u.ac.jp.
Abstract:
Accurate assessment of vital signs is important for reducing mortality. The aim of this study was to validate the effectiveness and safety of noncontact vital sign sensors. Interference tests were conducted with a noncontact vital sign sensor and medical devices. Inpatients' heart and respiratory rates were monitored via this sensor, and the measurements of this sensor were compared with those of reference medical equipment. Noncontact vital sign sensors and medical devices did not interfere with each other. A total of 21 patients (10 adults and 11 children, including 1 baby) were analysed. For all patients, the correlation coefficients for the HR and RR were 0.86 and 0.96, respectively. In adult patients, the correlation coefficients for the HR and RR were 0.75 and 0.96, respectively. In paediatric patients, the correlation coefficients for the HR and RR were 0.82 and 0.94, respectively. No effects of noncontact vital sign sensors on patients, surrounding patients or medical equipment were observed. Noncontact vital sign sensors are accurate and safe.
More Related Videos
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Electrophysiology of Normal Cardiac Rhythm