Rapid detection of multiple gas mixtures and evaluation of harmful gas removal efficiency in a deck decompression
Qu Liang1, Pingxiao Liu2, Lei Zhao3
1Anhui Province Key Laboratory of Medical Physics and Technology, Institute of Health and Medical Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, 230031, P.R. China. chyshen@aiofm.ac.cn.
Abstract:
The multiple gas mixtures in the deck decompression chamber (DDC) serve as a life-sustaining medium for divers to adapt to high-pressure environments and to safely decompress after saturation diving operations. However, due to the complexity of the gas composition and the wide concentration range, there is currently no technique that can rapidly detect all gases in the DDC. In this study, we developed a photoinduced chemical ionization (pCI) and electron impact (EI) dynamic switching mass spectrometry system. This technique was applied to investigate the spatial distribution uniformity of respiratory gases within the DDC at pressures of 0.13 MPa, 0.6 MPa, and 1.5 MPa, as well as the removal efficiency of toxic gases at 1.5 MPa. The switching stability time of pCI/EI dynamic switching mass spectrometry was 30 s per cycle, with optimal detection performance metrics including a detection limit down to 0.58 ppb (H2S), a fastest response time of 2 s (for CO2 and H2S), sensitivity up to 62.97 counts per ppb (H2S), and an overall concentration detection range spanning from 1.0 × 10-9 v/v (1 ppb) to 4.5 × 10-1 v/v (45%), covering the requirements for all target gases. At the three pressure levels, the spatial distribution uniformity of O2 in the DDC was 0.34%, 0.21%, and 0.08%, with the time to reach uniform distribution being 5 min, 3 min, and 1 min, respectively. For CO2, the spatial distribution uniformity was 0.62%, 1.61%, and 1.30%, with uniform distribution achieved in 10 min, 7 min, and 5 min, respectively. The removal efficiencies for harmful gases such as CO2, CH4, NH3, and H2S were 39.57%, 10.75%, 14.29%, and 3.96%, respectively. Under high-pressure conditions, O2 and CO2 rapidly achieved uniform distribution within the DDC. The pCI/EI dynamic switching mass spectrometry technology provides a rapid detection method for multicomponent gases in enclosed chambers like the DDC. This technology holds significant implications for the life support and operational efficiency of personnel involved in shipwreck salvage, underwater construction, and deep-sea exploration of marine resources.
More Related Videos
05:00Measuring Dissolved Methane in Aquatic Ecosystems Using An Optical Spectroscopy Gas Analyzer
Published on: July 26, 2024
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Performance Liquid Chromatography: Types of Detectors