Related Experiment Video
Updated: Apr 1, 2026

High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Coronary Stent Imaging with Photon-counting Detector CT
Judith van der Bie1, Simran Priyanka Sharma1,2, Alexander Hirsch1,2
1Department of Radiology & Nuclear Medicine, Erasmus University Medical Center, Dr Molewaterplein 40, Rm Nd-547, 3015 GD Rotterdam, the Netherlands.
Abstract:
Photon-counting detector (PCD) CT offers promising advancements in stent imaging over traditional CT by providing enhanced spatial resolution and spectral capabilities. This article aims to provide an overview of the current literature on coronary stent imaging using PCD CT technology. The high spatial resolution of PCD CT effectively reduces stent blooming artifacts and enhances in-stent visibility and restenosis assessment. To fully leverage the potential of PCD CT, it is crucial to use thin sections and sharp kernels. However, thin sections and sharp kernels increase image noise, potentially affecting qualitative assessment of the lumen. This higher noise could be mitigated by employing higher strengths of iterative reconstruction algorithms. Spectral reconstructions derived from PCD CT can also improve stent assessment using low monoenergetic images that boost the signal of iodinated contrast media within the stent lumen or high monoenergetic images that reduce metal artifacts, beam hardening, and blooming. These advancements of PCD CT offer potential benefits to clinical care by enhancing the diagnostic accuracy of CT technology for assessing metallic stents, potentially diminishing the need for invasive procedures. Keywords: CT, Interventional-Vascular, Stents, Vascular, Cardiac Supplemental material is available for this article. © RSNA, 2025.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
06:39Novel Percutaneous Approach for Deployment of 3D Printed Coronary Stenosis Implants in Swine Models of Ischemic Heart Disease
Published on: February 18, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...