Related Experiment Video
Updated: Feb 8, 2026

Targeting the Rat's Small Bowel: Long-Term Infusion into the Superior Mesenteric Artery
Published on: April 8, 2021
Ultrastructural changes in rat aortic endothelium during contrast media infusion
Abstract:
A rat model was employed to investigate contrast media (CM) induced ultrastructural changes in the vascular endothelium. Ionic contrast materials such as Renografin-76 (diatrizoate meglumine diatrizoate sodium), MD-76 (diatrizoate meglumine diatrizoate sodium), and Angiovist (meglumine diatrizoate) were injected into the femoral vein of anesthetized male Wistar rats (240-260 g) and allowed to circulate. Control animals were similarly injected with equiosmolar sucrose and physiologic saline. The thorax was opened 15 minutes, 1 hour, and 4 hours postinjection and cardiac perfusion performed using Karnovsky's fixative; the thoracic aorta was then surgically removed, and processed for transmission electron microscopy. All CM produced shrinkage in cell cytoplasm and nuclear structures thereby causing distortions in cell morphology. In control tissues, however, no such ultrastructural damages were noted. Within 15 minutes of CM infusion, electron dense granules were seen on the luminal surface of endothelial cells, in pinocytotic vesicles, as well as in the gap junctions between cells. These observations indicate that contrast media intake occurs via vesicular transport, and through the cell junction.
Related Concept Videos
Aortic Regurgitation III: Medical Management
Aortic Regurgitation I: Introduction
Microbial Growth Media
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Infusion
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...

