Related Experiment Video
Updated: Sep 20, 2025

Endotracheal Intubation Using a Flexible Intubation Endoscope as a Standardized Model for Safe Airway Management in Swine
Published on: August 25, 2022
Effect of real-time carbon dioxide sensing stylet-assisted endotracheal intubation: A case-crossover manikin
Yoonjic Kim1, Yoon Ha Joo1, Ki Hong Kim1
1Seoul National University Hospital Department of Emergency Medicine, Jongno-gu, Seoul 03080, South Korea.
Background:
Endotracheal intubation is an important emergency procedure, especially in critical care settings. Capnography-guided intubation (CGI) is a technology that may enhance procedural efficiency. This study aimed to compare the effectiveness of CGI with conventional intubation (CI) using a manikin simulation.
Methods:
A case-crossover manikin simulation study was conducted with three clinical scenarios: normal airway, cervical immobilization, and cardiopulmonary resuscitation. A CO2-exhalation simulation manikin was developed for this purpose. Participants were randomly assigned to perform CGI or CI first, followed by the alternative method. The primary outcome was the first-attempt success rate, and the secondary outcome was the procedure time of intubation. A linear mixed-effects model with a random effect for each subject was applied.
Results:
A total of 40 participants were enrolled, and 20 in each study group. The first-attempt success rate was higher with CGI than CI across all clinical situations, with statistically significant differences in the normal airway and cervical immobilization settings. Specifically, for the normal airway, the success rate was 40 (100.0 %) for CGI vs. 33 (82.5 %) for CI [abs diff: 17.5 %, 95 % CI: 5.7 %-29.3 %]; for cervical immobilization, 39 (97.5 %) vs. 32 (80.0 %) [abs diff: 17.5 %, 95 % CI: 4.2 %-30.8 %]; and for cardiopulmonary resuscitation, 40 (100.0 %) vs. 38 (95.0 %) [abs diff: 5.0 %, 95 % CI: -1.8 %-11.8 %]. The intubation time was shorter with CGI in the normal airway and cervical immobilization scenarios. The median [interquartile range (IQR)] time for normal airway was 23.5 (19.2-28.4) sec for CGI vs. 31.6 (22.2-59.7) sec for CI, and for cervical immobilization, 24.4 (20.4-30.8) sec for CGI vs. 28.6 (22.6-56.9) sec for CI. In cardiopulmonary resuscitation, the median [IQR] was 23.1 (19.6-31.4) sec for CGI vs. 25.1 (18.6-32.4) sec for CI.
Conclusion:
In the manikin-based randomized crossover simulation, CGI achieved a higher first-attempt success rate and shorter intubation time than CI in the normal airway and cervical immobilization scenarios.
Related Concept Videos
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Cardiopulmonary Resuscitation II: ACLS Airway Management