Performance of convolutional neural network-enhanced electrocardiography in detecting acute coronary syndrome:
Koichiro Hori1, Shinya Suzuki1, Naomi Hirota1
1Department of Cardiovascular Medicine, The Cardiovascular Institute, Tokyo, Japan.
Background:
Early and accurate diagnosis of acute coronary syndrome (ACS), particularly non-ST-elevation ACS (NSTE-ACS), remains a critical challenge in emergency settings. Despite advancements in diagnostic modalities, conventional electrographic (ECG) interpretation often fails to detect subtle ischemic changes, particularly in NSTE-ACS, highlighting the need for artificial intelligence (AI)-driven approaches.
Methods:
This study retrospectively analyzed data from a single-center cohort (Shinken Database 2010-2022, n = 32,167) to develop AI-driven ECG models for ACS detection. A convolutional neural network (CNN) model and an integrated neural network (INN) model, which incorporated diagnostic probabilities for ACS subtypes and target vessels, were evaluated using area under the receiver operating characteristics curve (AUROC), area under the precision-recall curve (AUPRC), sensitivity, and F1 scores for all‑lead ECG and reduced‑lead ECG models.
Results:
The CNN model using all‑lead ECG achieved an AUROC of 0.877, an AUPRC of 0.391, and an F1 score of 0.184, while the INN model showed similar results (AUROC 0.889, AUPRC 0.356, and F1 score 0.188). For subtypes related to NSTE-ACS, the CNN model using all‑lead ECG (CNN model using double‑lead ECG) model achieved an AUROC of 0.785 (0.783), sensitivity of 0.723 (0.672), and specificity of 0.699 (0.768) for unstable angina, and an AUROC of 0.795 (0.786), sensitivity of 0.527 (0.567), and specificity of 0.878 (0.849) for NSTE-myocardial infarction. Among patients with troponin testing (n = 4169), the CNN model achieved a sensitivity of 76 %, a positive predictive rate (PPR) of 32 %, and an F1 score of 0.452, while the INN model achieved 78 %, 35 %, and 0.483, respectively. The leads I and II model demonstrated the highest AUROC among reduced‑lead models (0.866), with F1 scores in patients with troponin testing of 0.395 and 0.390 for the CNN and INN models, respectively.
Conclusion:
Both CNN and INN-enhanced ECGs demonstrated good performance in detecting ACS including NSTE-ACS with subtle ischemic ECG changes. However, low PPR limit these models' standalone diagnostic utility. Instead, they hold promise as supportive tools, especially in resource-limited settings where reduced‑lead ECGs may be beneficial.
Related Concept Videos
Acute Coronary Syndrome III: Diagnostic Studies
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Acute Coronary Syndrome II: Pathophysiology and Clinical Manifestations
Acute Coronary Syndrome I: Introduction
Imaging Studies for Cardiovascular System V: CT