Related Experiment Video
Updated: Jul 6, 2026

06:58
Rapid Homogeneous Detection of Biological Assays Using Magnetic Modulation Biosensing System
Published on: June 13, 2010
9.7K
Plasmonic Optical Fibre-Based Point-of-Care Test for Periodontal MIP-1α Detection: A Validation Study of a
Marco Annunziata1, Francesco Arcadio2, Emanuela Stampone3
1Multidisciplinary Department of Medical-Surgical and Dental Specialties, University of Campania "Luigi Vanvitelli", Naples, Italy.
International Dental Journal
|June 3, 2025
Summary
A new plasmonic optical fibre test accurately detects macrophage inflammatory protein-1 alpha (MIP-1α) in saliva. This point-of-care test (POCT) shows promise for monitoring periodontal disease.
Area of Science:
- Biomedical Engineering
- Analytical Chemistry
- Nanotechnology
Background:
- Salivary diagnostics are crucial for non-invasive disease monitoring.
- Macrophage inflammatory protein-1 alpha (MIP-1α) is a key biomarker for periodontal disease.
- Existing diagnostic methods like ELISA can be time-consuming and require laboratory settings.
Purpose of the Study:
- To evaluate the analytical performance of a novel multiplexed plasmonic optical fibre-based point-of-care test (POCT).
- To compare the POCT's ability to detect and quantify salivary MIP-1α against the standard enzyme-linked immunosorbent assay (ELISA).
- To assess the potential of this POCT for rapid and reliable disease monitoring.
Main Methods:
- Development of a surface plasmon resonance (SPR) based biosensor using modified plastic optical fibres (POFs) functionalized with anti-MIP-1α antibodies.
- Quantification of MIP-1α in serial dilutions (0.25–10 pM) to establish a dose-response curve.
- Comparison of SPR-POF sensor results with ELISA for 50 human salivary samples.
- Analysis of MIP-1α levels in relation to patient demographics and periodontitis status.
Main Results:
- The SPR-POF biosensor demonstrated a strong positive correlation with ELISA (Spearman's rs = 0.894, P < .001).
- The SPR-POF test achieved a lower limit of detection (LoD) of 0.15 pM compared to ELISA's 0.78 pM.
- Significantly higher MIP-1α levels were observed in patients with periodontitis.
Conclusions:
- The developed 3-arm plasmonic POCT offers comparable accuracy and a lower LoD than ELISA for salivary MIP-1α detection.
- The multiplexed design enhances measurement rapidity and reliability, making it suitable for point-of-care applications.
- This novel SPR-POF prototype is valuable for future POCT development in monitoring periodontal health and disease.
Keywords:
Macrophage inflammatory protein-1 alphaPeriodontitisPoint-of-care testSalivaSurface plasmon resonance