Related Experiment Video
Updated: May 3, 2026

A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
SPECT/CT as Gatekeeper for Extrathecal Administration on 99m Tc-DTPA Cisternography
Irene García-Megias1, Ana María Cabada-Del Rio2, Jaime-Andrés Bonilla-Plaza1
1Department of Nuclear Medicine, University Hospital of Toledo, Spain.
Spontaneous intracranial hypotension is an entity caused by the loss of cerebrospinal fluid (CSF) volume. Cisternography presents an adequate diagnostic performance for the detection of CSF leaks. A 32-year-old woman with orthostatic headache of months of evolution, lumbar canal stenosis on magnetic resonance imaging and CSF hypotension suspicious of CSF leakage was referred to our department. Patient underwent 2 cisternographies: first was interpreted erroneously as CSF leakage being necessary procedure repetition and a retrospective review of SPECT/CT images for a correct diagnosis. This case illustrates the importance of checking the correct administration of the radiopharmaceutical with SPECT/CT for avoiding misdiagnosis.
Spontaneous intracranial hypotension is an entity caused by the loss of cerebrospinal fluid (CSF) volume. Cisternography presents an adequate diagnostic performance for the detection of CSF leaks. A 32-year-old woman with orthostatic headache of months of evolution, lumbar canal stenosis on magnetic resonance imaging and CSF hypotension suspicious of CSF leakage was referred to our department. Patient underwent 2 cisternographies: first was interpreted erroneously as CSF leakage being necessary procedure repetition and a retrospective review of SPECT/CT images for a correct diagnosis. This case illustrates the importance of checking the correct administration of the radiopharmaceutical with SPECT/CT for avoiding misdiagnosis.
More Related Videos
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...