Optimised oxygenation improves functional capacity during daily activities in patients with COPD on long-term oxygen
Linette Marie Kofod1,2, Ejvind Frausing Hansen3, Barbara Christina Brocki4
1PMR-C, Department of Physio- and Occupational Therapy, Copenhagen University Hospital, Hvidovre, Hvidovre, Denmark linette.marie.kofod@regionh.dk.
Background:
Minimising hypoxaemia during submaximal walking tests has a positive effect on exercise capacity and dyspnoea in patients with chronic obstructive pulmonary disease (COPD) on long-term oxygen therapy (LTOT). However, the impact of optimising oxygenation during everyday tasks remains unexplored. Therefore, we investigated the effects of maintaining a target saturation on activities of daily living (ADL) using automated oxygen titration compared with conventional fixed oxygen flow.
Methods:
In a double-blinded, randomised crossover trial, patients with COPD on LTOT performed two GlittreADL tests to assess the functional capacity of everyday activities using (1) their fixed oxygen dose and (2) an adjusted flow from 0 to 8 L/min targeting a peripheral oxygen saturation (SpO2) of 90-94%. A closed-loop device automatically titrated the oxygen based on information from a Bluetooth wrist pulse oximeter.
Results:
31 patients (mean±SD age: 72.8±5.9 years, forced expiratory volume in 1 s of % predicted: 36.7±12.7) were included. The patients reduced the time to perform the ADL test by median (IQR) 38 (12-73) s, p<0.001, using automated titration compared with the fixed oxygen flow. The oxygen flow in the automated arm more than tripled to 5.4 (4.1-6.8) versus 1.6 (1.1-2.1) L/min (fixed) during the test, p<0.001, while the time spent within SpO2-target was increased from 19% to 49%, p=0.002. Correspondingly, the patients experienced less dyspnoea (BorgCR10); 5 (3-7) versus 6 (4-8), p<0.001, in favour of the automated oxygen titration.
Conclusions:
Improving oxygenation and extending the time spent within target saturation reduced dyspnoea and improved functional capacity in ADL in patients with COPD on LTOT.
Trial Registration Number:
NCT05553847.
More Related Videos
08:44Author Spotlight: Integrating Alveolar-Capillary Reserve Measurements in Exercise Adaptation and Therapeutic Strategies
Published on: February 2, 2024
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
COPD: Management Using Bronchodilators and Corticosteroids
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Physiological Control of Respiration
Breathing, a seemingly passive process, is regulated by the respiratory center in the brainstem. This center coordinates the involuntary control of respirations, which means it occurs without conscious effort, ensuring a smooth and uninterrupted pattern.
Regulation of Ventilation
The body maintains ventilation by monitoring levels of carbon dioxide (CO2), oxygen (O2), and hydrogen ion concentration (pH) in the arterial blood. Among these factors, the level of CO2 plays a crucial...
Respiratory Capacities
One key metric is the Inspiratory Capacity (IC), which represents the maximum amount of air that can be inhaled with full effort. IC is calculated by summing the tidal volume and inspiratory reserve volume, typically ranging from 2.4 to 3.6 liters.
The Functional Residual Capacity (FRC) represents the air in the...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...