Related Experiment Video
Updated: Sep 19, 2025

Measuring Carbon-based Contaminant Mineralization Using Combined CO2 Flux and Radiocarbon Analyses
Published on: October 21, 2016
CFD modeling of indoor radon distribution in a laboratory with granite countertops
Bahareh Azarvand-Hassanfard1, Mojtaba Gholami2
1Department of Physics, Payame Noor University, Tehran, Iran. b.azarvand@pnu.ac.ir.
Abstract:
Radon gas, a significant source of indoor radiation exposure, poses serious health risks, particularly lung cancer. This study employs Computational Fluid Dynamics (CFD) using the ANSYS Fluent software to model the behaviour and distribution of radon gas in a laboratory space equipped with granite countertops. A three-dimensional model of the laboratory, including its geometry, ventilation rates, and radon exhalation sources, was developed to simulate radon concentrations, particularly at breathing height. Radon exhalation rate from the granite and other surfaces in the room was measured experimentally. Numerical results, validated by experimental measurements, revealed a 30% increase in average radon concentration following the installation of granite countertops with an exhalation rate of 6.5 Bq m-2 h-1. The spatial distribution of radon, particularly near the countertops, indicated regions where radon accumulated at concentrations exceeding the action threshold of the US Environmental Protection Agency of 148 Bq/m3. Additionally, while natural ventilation effectively reduced overall radon levels, its efficiency was diminished near the countertops due to complex airflow patterns, leading to radon accumulation in breathing zones. This study demonstrates the ability of numerical methods to identify centers of radon gas accumulation by predicting airflow patterns and behaviours at various ventilation rates, emphasizing the need for effective ventilation strategies, such as localized exhaust systems, to reduce radon exposure in critical areas.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
10:24Neutron Radiography and Computed Tomography of Biological Systems at the Oak Ridge National Laboratory's High Flux Isotope Reactor
Published on: May 7, 2021
Related Concept Videos
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Radioactivity and Nuclear Equations
A nuclide of an element has a specific number of protons and...
Radiation: Applications
The average...
Maxwell-Boltzmann Distribution: Problem Solving
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
Measurement of Air Content in Concrete
The pressure method,...