Realistic electric field characterization of clinically used deformable large TMS coils in a large cohort
Torge Worbs1, Bianka Rumi2, Kristoffer H Madsen3
1Section for Magnetic Resonance, DTU Health Tech, Technical University of Denmark, Kgs Lyngby, Denmark; Danish Research Centre for Magnetic Resonance, Department of Radiology and Nuclear Medicine, Copenhagen University Hospital Amager and Hvidovre, Copenhagen, Denmark.
Background:
Transcranial Magnetic Stimulation (TMS) therapies use both focal and unfocal coil designs. Unfocal designs often employ bendable windings and moveable parts, making realistic simulations of their electric fields in inter-individually varying head sizes and shapes challenging. This hampers comparisons of the various coil designs and prevents systematic evaluations of their dose-response relationships.
Objective:
Introduce and validate a novel method for optimizing the position and shape of flexible coils taking individual head anatomies into account. Evaluate the impact of realistic modeling of flexible coils on the electric field simulated in the brain.
Methods:
Accurate models of four coils (Brainsway H1, H4, H7; MagVenture MST-Twin) were derived from computed tomography data and mechanical measurements. A generic representation of coil deformations by concatenated linear transformations was introduced and validated. This served as basis for a principled approach to optimize the coil positions and shapes, and to optionally maximize the electric field strength in a region of interest (ROI).
Results:
For all four coil models, the new method achieved configurations that followed the scalp anatomy while robustly preventing coil-scalp intersections on 1100 head models. In contrast, setting only the coil center positions without shape deformation regularly led to physically impossible configurations. This also affected the electric field calculated in the cortex, with a median peak difference of ∼16 %. In addition, the new method outperformed grid search-based optimization for maximizing the electric field of a standard Fig. 8 coil in a ROI with a comparable computational complexity.
Conclusion:
Our approach alleviates practical hurdles that so far hampered accurate simulations of bendable coils. This enables systematic comparison of dose-response relationships across the various coil designs employed in therapy.
More Related Videos
Related Concept Videos
Electric Field Lines
The solution to this problem is to use electric field lines, which are not vectors but...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Magnetic Field Lines
Magnetic field lines follow several hard-and-fast rules:
Toroids
When connected to a supply, the magnetic field generated in the toroid has field lines circular and concentric to its axis. Conventionally, the direction of this magnetic field is expressed using the right-hand rule. If the fingers of the right hand curl in the current direction, the thumb points in the...
Magnetic Field Due to Two Straight Wires
Transmission Line Design Considerations