Background:
We investigated whether the shape of arterial blood input curves affects the diagnostic performance of myocardial blood flow (MBF) on rubidium-82 (82Rb) positron emission tomography (PET) myocardial perfusion imaging (MPI) for obstructive coronary artery disease (CAD).
Methods And Results:
We retrospectively enrolled 386 patients without prior CAD who underwent 82Rb PET-MPI and invasive coronary angiography within 6 months, from 2010 to 2018. Abnormal shapes of stress left atrial blood pool (BP) time activity curve were characterized into five categories based on visual/quantitative assessment: (1) low stress/rest peak ratio (SRPR), (2) slow activity rise, (3) slow activity decline, (4) broad peak and (5) multiple peaks. The SRPR was defined as the ratio of peak count value on the stress BP activity by rest BP activity. A low SRPR was defined as one below the median value (0.82). We compared the diagnostic performance of stress MBF and myocardial flow reserve for detecting obstructive CAD (≥70% stenosis) using area under the curve (AUC) analysis.
Results:
Among the five abnormal categories, the AUC of stress MBF in the low SRPR group (n = 193) was lower than in the normal SRPR group (n = 193) in per-patient (.67 [.59-.74] vs. .78 [.70-.84], P = .0499, respectively) and per-vessel analyses (.68 [.63-0.73] vs. .75 [.71-.79], P = .0352, respectively). The AUC in slow activity rise group (n = 167) for stress MBF was lower than in others in per-vessel analysis (n = 219) (.68 [.62-.72] vs. .75 [.70-.79], P = .0270). Other abnormal profiles showed no significant differences (all P > .05).
Conclusions:
Low SRPR and slow activity rise were associated with reduced diagnostic performance of stress MBF.
More Related Videos
10:21Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
Published on: August 8, 2019
11:09High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System V: CT