Quantitative analyses of the distal bipolar electrogram for focal premature ventricular contraction ablation
Sun Young Jeong1, Nigel Gupta2, Zhilin Qu3
1Department of Cardiology Kaiser Permanente Los Angeles Medical Center Los Angeles California USA.
Background:
Accurate interpretation of the distal bipolar electrogram (bi-EGM) is essential for successful ablation of idiopathic focal PVC. Sharp, early, and fractionated bi-EGM is often considered to be near-field and targeted, but in an empiric fashion rather than by quantitative criteria.
Objectives:
To quantify the distal bi-EGM with five parameters to elucidate quantitative criteria distinguishing near-field from far-field bi-EGM.
Methods:
The distal bi-EGM was quantified and analyzed using: half time of activation (t ½), slope factor (S, derived by fitting the Boltzmann equation), linear slope (dV/dt), time from onset of bi-EGM to surface ECG (T s) and number of deflections (De#).
Results:
Among 41 patients, 26 were ablated successfully and 15 unsuccessfully. t ½ and S, defining the sharpness of the activation process, were significantly different between the two groups (3.2 ± 0.3 vs. 5.9 ± 0.6 ms, p < 0.001 and 0.8 ± 0.1 vs. 4.8 ± 2.0, p = 0.01). T s was earlier in the successful group (35.6 ± 1.3 vs. 25.8 ± 1.6 ms, p < 0.01). dV/dt and De# were not statistically different (0.2 ± 0.04 vs. 0.1 ± 0.02 mV/ms, p = 0.06; and 2.7 ± 0.2 vs. 2.3 ± 0.3, p = 0.22). The 5 parameters showed indifference across anatomic locations. AUCs of ROC curve are >0.8 (t ½ 0.85, S 0.85 and T s 0.87).
Conclusion:
t ½, S and T s are precise in quantifying the sharpness and earliness of distal bi-EGM; therefore, discriminating the near-field from far-field bi-EGM for guiding successful ablation.
More Related Videos
12:45Benefits of Cardiac Resynchronization Therapy in an Asynchronous Heart Failure Model Induced by Left Bundle Branch Ablation and Rapid Pacing
Published on: December 11, 2017
09:17High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
