Low-keV Virtual Monoenergetic Imaging for Bronchial Artery Visualization on Photon-Counting Detector Computed
Xuyang Sun1, Tetsu Niwa1, Takakiyo Nomura1
1Department of Diagnostic Radiology, Tokai University School of Medicine, 143 Shimokasuya, Isehara 259-1193, Japan.
Abstract:
Background/Objectives: This study aims to determine the optimal use of virtual monoenergetic imaging (VMI) for visualizing the bronchial artery on photon-counting detector computed tomography (PCD-CT). Methods: We evaluated the visibility of the bronchial artery on PCD-CT in 34 consecutive patients with esophageal cancer (twenty-eight men, six women; mean age, 70.2 years) prior to surgery. Region-of-interest measurements were taken at the right bronchial artery at the tracheal bifurcation level, mediastinal fat, and the erector spinae muscles on contrast-enhanced early-phase CT. We compared the CT attenuation of the bronchial artery, image noise, and contrast-to-noise ratio (CNR) across VMI at 40, 50, 60, and 70 keV. Additionally, two radiologists performed a subjective image quality assessment by comparing VMI at 40, 50, and 60 keV with 70 keV, rating bronchial artery enhancement, border clarity, peripheral visibility, and image noise. Results: CT attenuation, image noise, and CNR significantly differed across VMI energy levels (p < 0.00001). Lower-keV VMI demonstrated higher CT attenuation and increased noise but also higher CNR (all p < 0.05). Both radiologists rated bronchial artery enhancement, border clarity, and peripheral visibility higher at 40 and 50 keV than at 70 keV, with the highest scores observed at 40 keV (all p < 0.05). Observer 1 noted slightly increased noise at 40 and 50 keV, while observer 2 observed this effect at 40 keV compared with 70 keV. Conclusions: Low-keV (40-50 keV) VMI on PCD-CT enhances bronchial artery visualization.
More Related Videos
09:08Author Spotlight: Standardization and Best Practices for Advancing Lung Imaging Using 129Xe MRI
Published on: November 21, 2023
02:09Multi-modal Pulmonary Imaging: Using Complementary Information from CT and Hyperpolarized 129Xe MRI to Evaluate Lung Structure-Function
Published on: April 12, 2024
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies III: Computed Tomography