Related Experiment Video
Updated: Jun 16, 2025

Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Periradicular Temperature Changes and Risk Management During Heat-Inducing Endodontic Disinfection Procedures In
Theresia Saban1, Lea Külzer1, Andreas Braun1
1Department of Operative Dentistry, Periodontology and Preventive Dentistry, RWTH Aachen University, 52074 Aachen, Germany.
Abstract:
Background/Objectives: The aim of this study was to investigate the effects of periodontal blood flow on the periapical region during various endodontic disinfection procedures. The hypothesis that periodontal blood flow reduces the increase in root surface temperature during disinfection procedures was tested. Methods: One hundred and twenty extracted human teeth were shortened to 11 mm and the root canal was prepared using the F4 ProTaper Gold system. The specimens were covered with wax and then sealed in a thermoforming sheet, leaving a gap of 0.2 mm. Cannulas were attached to simulate stable fluid circulation. Thermographic evaluation was carried out using an infrared camera. The following methods were chosen for disinfection: I, λ445 nm diode laser (0.6 W, cw); II, λ445 nm diode laser, 3 W, pulsed, duty cycle 50%, 10 Hz; III, λ445 nm diode laser, 3 W, pulsed, duty cycle 75%, 10 Hz; IV, λ970 nm diode laser, 2 W, pulsed, duty cycle 50%, 10 Hz; V, λ970 nm diode laser, 2 W, pulsed, duty cycle 75%, 10 Hz; VI, experimental plasma device (2.5 W, 3.7 V); VII, heat plugger (200.0 °C); VIII, NaOCl 3% (60 °C). The results were analyzed statistically using the Kruskal-Wallis test. When there were significant differences between the groups (p < 0.05), the pairwise Mann-Whitney test with sequential Bonferroni correction was applied. Results: The smallest temperature changes, with a median value of 0.82 °C (max. 2.02 °C, min. 0.15 °C, IQR 0.87 °C), were observed using the laser at a setting of λ445 nm, 0.6 W cw, and a circulation rate of 6 mL/min. The highest temperature changes were measured at a fluid circulation rate of 0 mL/min with a laser setting of λ445 nm, 3 W, pulsed, duty cycle 75% with a median value of 21.7 °C (max. 25.02 °C, min. 20.29 °C, IQR 2.04 °C). Conclusions: Disinfection procedures with laser, NaOCl, and an experimental plasma device can lead to an increase in root surface temperature. With the exception of the heat plugger, no significant temperature changes were observed. This study was conducted in vitro, which may limit the direct applicability of the results to clinical scenarios. Nevertheless, the simulation of blood flow showed a thermally protective effect, suggesting that clinical protocols should consider this variable when selecting thermal disinfection methods. These results support the hypothesis that periodontal blood flow may have a potentially positive influence on temperature changes during disinfection procedures.
More Related Videos
06:43Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
11:46Investigation of the Electrophysiological and Thermographic Safety Parameters of Surgical Energy Devices During Thyroid and Parathyroid Surgery in a Porcine Model
Published on: October 13, 2022
Related Concept Videos
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Factors Affecting Body Temperature
Factors may include:
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...