Transthoracic Speckle Tracking Echocardiography for the Quantitative Assessment of Left Ventricular Myocardial Deformation
Published on: October 20, 2016
Speckle-Tracking Echocardiography in Dogs: Evaluating Imaging Parameters and Methodological Variability in Global
Jonas E Mogensen1, Maiken B T Bach1, Pernille G Bay1
1Department of Veterinary Clinical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Dyrlægevej 16, 1870 Frederiksberg, Denmark.
Image foreshortening and heart rate variability significantly impact two-dimensional speckle-tracking echocardiography (2D-STE) measurements of global longitudinal strain (GLS). Optimizing image acquisition is crucial for reliable 2D-STE analysis.
Area of Science:
- Cardiology
- Medical Imaging
- Veterinary Ultrasound
Background:
- Two-dimensional speckle-tracking echocardiography (2D-STE) provides quantitative myocardial function assessment.
- Analyzing speckle motion during ultrasound interactions offers insights into cardiac performance.
- Reliable 2D-STE requires understanding technical parameter influences on strain measurements.
Purpose of the Study:
- To evaluate the reliability of 2D-STE for global longitudinal strain (GLS) measurement.
- To assess the impact of technical parameters on 2D-STE accuracy.
- To compare two GE Healthcare speckle-tracking methods: 2D strain and automated function imaging (AFI).
Main Methods:
- Prospective study in two cohorts of healthy dogs (n=16 and n=10).
- Assessed influence of frame rate, heart rate variability, zoom, frequency, and foreshortening on 2D-STE.
- Compared 2D strain and AFI for agreement and observer variability.
Main Results:
- Foreshortening (p < 0.01) and heart rate variability (p = 0.02) significantly affected speckle-tracking measurements.
- Zoom, frame rate, and frequency did not show significant impact.
- AFI systematically underestimated GLS compared to 2D strain, despite strong correlation; intra-/inter-observer CVs were <9%.
Conclusions:
- Foreshortening and heart rate variability are critical factors affecting 2D-STE GLS accuracy.
- While both 2D strain and AFI are reliable, image acquisition optimization is essential.
- Careful selection of imaging parameters and criteria enhances the dependability of speckle-tracking analysis.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
12:12Echocardiographic Approaches and Protocols for Comprehensive Phenotypic Characterization of Valvular Heart Disease in Mice
Published on: February 14, 2017
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...