The effects of transitioning from SITA-Standard to SITA-Fast or SITA-Faster on sensitivities below the measurement
Chris Bradley1, Alex Pham1, Jithin Yohannan1,2
1Wilmer Eye Institute, Johns Hopkins University School of Medicine, 600 N Wolfe Street, Baltimore, MD, USA.
Objective:
Determine how sensitivities below the measurement floor of the Humphrey Field Analyzer change when transitioning from Swedish Interactive Thresholding Algorithm (SITA) Standard to SITA-Fast and SITA-Faster strategies.
Design:
Retrospective descriptive study.
Participants:
A total of 21,468 24-2 SITA-Standard, 4872 SITA-Fast and 3468 SITA-Faster VFs from 7917 glaucoma and glaucoma suspect eyes with at least 5 VFs between 1997 and 2023 at the Wilmer Eye Institute.
Methods:
At each test location of the 24-2 test pattern, we measured the probability that <0 dB at a given test location on two baseline SITA-Standard VFs was M dB or higher on the first SITA-Fast or SITA-Faster post-baseline VF for different values of M > 0. Results were compared to using the same test strategy for both baseline and post-baseline VFs.
Main Outcome Measures:
Probability of <0 dB at baseline being measured as M > 0 dB or higher on the first post-baseline VF.
Results:
At M = 7 dB, which was approximately one standard deviation above the mean for post-baseline SITA-Standard sensitivities, average percent change from <0 dB across all test locations was 10.3 % for SITA-Standard, 15.8 % for SITA-Fast and 25.5 % for SITA-Faster. Percent change from <0 dB for all M tested (up to M = 20) was consistently higher near the macula compared to overall averages: on average 1.3 % higher for SITA-Standard, 1.5 % higher for SITA-Fast, and 6.3 % higher for SITA-Faster.
Conclusions:
Increased caution is advised when following the progression of <0 dB defects during a transition from SITA-Standard to SITA-Fast or SITA-Faster.
More Related Videos
10:05Measurement & Analysis of the Temporal Discrimination Threshold Applied to Cervical Dystonia
Published on: January 27, 2018
08:40Quantifying Arms and Legs Contributions during Repetitive Electrically-Assisted Sit-To-Stand Exercise in Paraplegics: A Pilot Study
Published on: November 11, 2022
Related Concept Videos
Distance Measurements by Taping
Distance Corrections
Electronic Distance Measuring Instruments
Differential Leveling
Influence of Earth's Curvature and Atmospheric Refraction on Leveling
Common Leveling Mistakes and Errors