Related Experiment Video
Updated: Sep 19, 2025

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Diagnostic Accuracy of Isotropic FLAIR-T2* Fusion Imaging for Central Vein Sign Detection in Multiple Sclerosis:
Yunus Emre Senturk1, Ahmet Peker2, Hande Ozen Atalay2
1Department of Radiology, Koç University Hospital, Davutpasa Street, No 4, 34010, Istanbul, Turkey. ysenturk@kuh.ku.edu.tr.
Purpose:
The central vein sign (CVS) is a promising imaging biomarker for multiple sclerosis (MS) diagnosis. While isotropic T2* at 3 T and 7 T has demonstrated high diagnostic performance, its utility at 1.5 T remains unclear. This study evaluates the performance of unenhanced FLAIR-T2* fusion at 1.5 T compared to 3 T in MS participants.
Methods:
This prospective observational study included 20 MS patients and 20 control subjects. Each participant underwent unenhanced isotropic Epi-T2* and isotropic FLAIR (0.8 mm voxel size) at both 1.5 T and 3 T. Subsequently, the derived isotropic T2* and FLAIR were combined to create the final FLAIR-T2* fusion in both magnetic field strengths. Two independent raters assessed the CVS status of white matter (WM) lesions using NAIMS criteria. WM lesions were classified as CVS+ or CVS-, and two methods-select-n* and CVS+ proportion-were applied. Sensitivity and specificity were computed, and CVS performance was compared across WM lesion locations.
Results:
Among eligible WM lesions (MS: 258; controls: 255), the mean CVS+ lesion proportion per participant was 66.9 ± 15.4% for 1.5 T FLAIR-T2* and 77.0 ± 13.6% for 3 T FLAIR-T2* (p < 0.01). At a 40% threshold, 1.5 T FLAIR-T2* achieved 90% sensitivity and 95% specificity, while 3 T FLAIR-T2* achieved 100% sensitivity and 95% specificity. The Select-6* method resulted in only one MS patient being misclassified at both field strengths. 3 T FLAIR-T2* detected more CVS+ lesions in deep WM (87.5% vs. 57.1%, p = 0.05).
Conclusion:
1.5 T FLAIR-T2* fusion demonstrates high performance in CVS assessment, although slightly outperformed by 3 T FLAIR-T2*. The select-6* method may enhance 1.5 T performance, supporting its feasibility for CVS evaluation.
More Related Videos
Related Concept Videos
Venous Thrombosis II: Clinical Manifestations and Diagnostic Studies
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies VII: Vascular Imaging
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies IV: Magnetic Resonance Imaging