Related Experiment Video
Updated: Jul 23, 2026

Retinal Detachment Model in Rodents by Subretinal Injection of Sodium Hyaluronate
Published on: September 11, 2013
ROLE OF AXIAL LENGTH ON POSTSURGICAL RETINAL DISPLACEMENT IN EYES TREATED FOR RHEGMATOGENOUS RETINAL DETACHMENT
Maura Mancini1, Gregorio Lo Giudice2, Claudio Brancato3
1Department of Biomedical Sciences, Ophthalmology Clinic, University of Messina, Messina, Italy.
Purpose:
This study examines the role of axial length in the detection of retinal displacement in patients treated for rhegmatogenous retinal detachment with pars plana vitrectomy.
Methods:
A total of 39 eyes from 39 patients undergoing pars plana vitrectomy with tamponade using either 16% diluted hexafluoroethane gas (C 2 F 6 ) or 1000-centistoke silicone oil were included. Retinal displacement and its direction were assessed via blue-fundus autofluorescence imaging. The evaluated variables included AL, demographic data, white-to-white distance, trocar gauge (23 G vs. 25 G), type of retinopexy, intraoperative use of perfluorocarbon liquid, number of detached quadrants, type of tamponade, postoperative metamorphopsia, and best-corrected visual acuity.
Results:
Retinal displacement was detected in 28.2% of patients (11/39), with 90.9% (10 patients) having undergone gas tamponade ( P = 0.004). Axial length was significantly associated with the detection of retinal displacement ( P < 0.0001). Among the 21 patients who received gas tamponade, the incidence of displacement was 80% in those with AL >26 mm compared with 18.2% in those with AL ≤26 mm ( P = 0.018). The intraoperative use of perfluorocarbon liquid also showed a positive correlation with retinal displacement ( P = 0.002). Retinal displacement did not negatively affect best-corrected visual acuity but was significantly associated with postoperative metamorphopsia ( P < 0.0001).
Conclusion:
Postoperative retinal displacement is significantly influenced by the type of tamponade, being more frequent with gas tamponade, and by the intraoperative use of perfluorocarbon liquid. Axial length was associated with the detection of retinal displacement, although its causal role remains uncertain.
More Related Videos
05:56Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model
Published on: April 3, 2016
07:13An Alternative and Validated Injection Method for Accessing the Subretinal Space via a Transcleral Posterior Approach
Published on: December 7, 2016
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment
Accessory Structures of the Eye