Transcutaneous Monitoring of Carbon Dioxide to Optimize Ventilator Weaning in At-Risk Adults After Cardiopulmonary
Emlyn Mann1, Christina Kelley, Lauren Gray
1Author Affiliations: Sharp Chula Vista Medical Center (Mss Gray and Westcott, Dr Kelley and Dr Graham), Point Loma Nazarene University, San Diego (Ms Mann and Dr Kelley); and San Diego State University (Dr Graham), California.
Background:
Cardiopulmonary bypass use during surgery disrupts microcirculation, which can contribute to lung injury, particularly in patients with pulmonary comorbidities. Continuous transcutaneous carbon dioxide (CO2) monitoring assists clinicians to trend values related to metabolic and respiratory status between intermittent arterial blood gas measurements. We sought to review the literature to support adoption of this technology to optimize weaning in patients with pulmonary comorbidities following open heart surgery.
Methods:
Multiple databases were reviewed. Inclusion criteria were limited to results of peer-reviewed articles in English published within the past 5 years. The findings were presented to relevant levels of hospital leadership, who approved adoption of the technology for this population. From there, monitors were positioned in 4 surgical intensive care unit rooms for monitoring of patients up to the point of extubation.
Results:
The literature review yielded 12 articles, with a majority deeming transcutaneous monitoring feasible and appropriate in the postoperative patient, including those having cardiopulmonary bypass. Clinical interventions and trending were valuable additions to improve patient outcomes and nursing autonomy. During the fiscal quarter following adoption of the technology, mean time spent on the ventilator dropped 30%, reintubation dropped 4%, and mortality decreased by 24%.
Conclusions:
Transcutaneous monitoring of CO2, with improved specificity over end-tidal CO2 monitoring, offers meaningful trending to inform clinician decision-making around readiness to wean. Additionally, transcutaneous monitoring allows for noninvasive, reliable continuous metabolic monitoring to serve as an early clinical indicator for at-risk patients.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Acute Respiratory Failure-III
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...